Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Anetsberger Brothers, modell SLG40

Hersteller: Anetsberger Brothers
Dateigröße: 541.62 kb
Dateiname: 8b6958e7-af0c-475e-a25a-c8c20a150e63.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Otherwise, melt shortening into its liquid state and refill the kettle before fryer operation is scheduled during the next normal working shift. 12. Attach the basket hanger to the top of the backsplash panel. Return the screen and fryer baskets to their proper positions on the basket hanger. 13. Perform the Lighting Procedure to return the fryer to operation, when desired. FR FRFRFRFRFRYER OPERA YER OPERAYER OPERAYER OPERAYER OPERAYER OPERATING INSTR TING INSTRTING INSTRTING INSTRTING INSTRTING INSTRUCTIONS UCTIONSUCTIONSUCTIONSUCTIONSUCTIONS (Continued) MONTHLY MAINTENANCE INSTRUCTIONS NOTE: Regular maintenance is recommended to keep the fryer operating properly. Once each month, before beginning fryer operation, check the flue (behind the backsplash panel) to ensure that it is clear and free of obstructions, enabling exhaust combustion gases to flow freely toward the ventilation hood area. DO NOT allow the flue to become excessively dirty. Monthly, observe the condition of the ventilation hood. If it shows evidence of a great deal of greasy residue, remove (clean) the residue to allow free flow of ventilation air. FR FRFRFRFRFRYER YERYERYERYERYER TR TRTRTRTRTROUBLESHOO OUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOTING GUIDE TING GUIDETING GUIDETING GUIDETING GUIDETING GUIDE All service (repairs or part replacement) must be performed by a qualified Service Agency. PROBLEM CAUSE REMEDY 1. Dirty/sooty pilot burner. Pilot flame does not 1. Clean the pilot burner. Perform stay lighted. the Lighting Procedure. 2. Low gas supply pressure [less than 6” 2. Measure the gas supply pres- W.C. for natural gas (11” W.C. for pro- sure. pane) when all other gas-powered equip- Contact your local gas supplier ment is operating.]. to obtain adequate gas supply volume and pressure. 3. Pilot flame too small to heat thermo pile. 3. Adjust the pilot valve (part of the gas safety valve) to increase the flame size: Unscrew and retain the large threaded cover; turn the pilot valve adjustment screw two turns counterclockwise; reinstall the threaded cover. 4. Pilot flame ‘wavering’ (being blown about 4. Block or redirect the draft, to by a draft). keep the flame burning steadily. 5. Improper thermopile output voltage (must 5. Replace the thermopile. be at least 180 millivolts, measured at the thermocouple junction block). 6. High-limit thermostat problem has shut off 6. Check for, and repair, any dam- the gas. aged high-limit thermostat wiring. Otherwise, test the high- limit thermostat by bypassing the high-limit thermostat (black and blue wires) at the gas control valve with a jumper wire. Next, perform the Lighting Procedure, to check whether the pilot flame lights. If the pilot flame lights and stays lit, the high-limit thermostat has failed and must be replaced. 7. Gas control valve has failed. 7. Replace the gas control valve. CAUTION: DO NOT return the fryer to normal operation with its high-limit thermostat bypassed. ! FR FRFRFRFRFRYER YERYERYERYERYER TR TRTRTRTRTROUBLESHOO OUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOTING GUIDE TING GUIDETING GUIDETING GUIDETING GUIDETING GUIDE (Continued) PROBLEM Pilot flame goes out repeatedly. Main burners do not ignite. CAUSE 1. Low gas supply pressure [less than 6” W.C. for natural gas (11” W.C. for propane) when all other gas-powered equipment is operating.]. 2. Loose thermocouple or high-limit thermostat connection(s) on gas control valve. 3. Pilot flame does not continuously touch the thermocouple because of excessive air flow around the pilot burner assembly. 4. High-limit thermostat problem has shut off the gas. ! CAUTION: DO NOT return the fryer to normal operation with its high-limit thermostat bypassed. 1. Gas control valve knob set to OFF or PILOT. 2. Low gas supply pressure [less than 6”W.C. for natural gas (11” W.C. for propane) when all other gas-powered equipment is operating.]. 3. Pilot burner problem. 4. Thermostat control set below the temperature of the liquid shortening in the kettle. REMEDY 1. Measure the gas supply pressure. Contact your local gas supplier to obtain adequate gas supply volume and pressure. 2. Check and tighten the connections. 3. Block the excessive air flow to make the pilot flame contact the thermocouple. 4. Check for, and repair, any damaged high-limit thermostat wiring. Otherwise, test the high- limit thermostat by bypassing the high-limit thermostat (black and blue wires) at the gas control valve with a jumper wire. Next, perform the Lighting Procedure, to check whether the pilot flame lights. If the pilot flame lights and stays lit, the high-limit thermostat has failed and must be replaced. 1. Perform the normal Lighting Procedure. Turn the gas control valve knob to ON to light the main burners. If the burners do not light, the gas safety valve has failed and must be replaced. 2. Measure the gas supply pressure. Contact your local gas supplier to obtain adequate gas supply volume and pressure. 3. Refer to the preceding Pilot Burner problems a...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien