Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Dito Dean, modell SR52

Hersteller: Dito Dean
Dateigröße: 355.24 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Model Gas Type Orifice Size Manifold Pressure KPa Manifold Pressure Inches WC SR62 Nat 2.53 mm 0.9 KPa 3.6” SR62 Prop 1.6 mm 2.4 KPa 9.6” CE UNITS ONLY: Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings and Pilot Markings are listed in the table below: MODEL* NOMINAL HEAT INPUT- Qn (kW) GAS TYPE ORIFICE SIZE (MM) MANIFOLD GAS PRESSURE ORIFICE QTY/ COLOR BURNER MARKING PILOT MARKING MBAR INCH W.C. SR62 GM 37.5 G20 G25 G31 2.40 2.40 1.51 12,0 17,5 22,0 4,8 7,0 8,8 5/BLUE 5/BLUE 5/RED Blue Blue Red 26N 26N 16LP SR52 GM 30 G20 G25 G31 2.40 2.40 1.51 12,0 17,5 22,0 4,8 7,0 8,8 4/BLUE 4/BLUE 4/RED Blue Blue Red 26N 26N 16LP SR42 GM 26 G20 G25 G31 2.40 2.40 1.51 12,0 17,5 22,0 4,8 7,0 8,8 3/BLUE 3/BLUE 3/RED Blue Blue Red 26N 26N 16LP *SR prefix- Super Runner Series *GM suffix- gas millivolt system with no electrical supply connections required NON-CE UNITS ONLY: Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are listed in the table below: MODEL* NOMINAL HEAT INPUT- Qn (BTU) GAS TYPE ORIFICE SIZE (MM) MANIFOLD GAS PRESSURE (INCH W.C.) ORIFICE QUANTITY PILOT MARKING SR62 GM 150 NAT LP 2.53(#39) 1.51(#53) 4 11 5 5 26N 16LP SR52 GM 120 NAT LP 2.53(#39) 1.51(#53) 4 11 4 4 26N 16LP SR42 GM 105 NAT LP 2.80(#35) 1.70(#51) 4 11 3 3 26N 16LP *SR prefix- Super Runner Series *GM suffix- gas millivolt system with no electrical supply connections required NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is operating. 1.4 Connection to the Gas Supply Line NOTE: The gas supply (service) line must be the same size or greater than the fryer inlet line. This appliance is equipped with a .-inch (15mm) inlet. The gas supply line must be sized to accommodate all gas- fired equipment connected to the line. Consult the local gas company or supplier, or your local contractor for minimum supply line requirements. NOTE: If quick-disconnect supply lines or flex lines are used, increase supply line size to .-inch (22-mm) or larger. Propane Applications; Proper Regulator Must Be Installed 1-3 SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS DANGER A manual shut-off valve must be installed in the gas supply (service) line upstream of this appliance and in a position where it can be reached quickly in the event of an emergency. DANGER The fryer must be connected to the gas supply specified on the rating and serial number plate located on the inside of the appliance door. DO NOT ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! DANGER Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas valve will cause improper and potentially dangerous operation. DANGER All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested for leaks using a solution of soapy water before lighting any pilots. Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service. Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position. 1.5 Gas Conversion Procedures DANGER This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual. CE UNITS ONLY: See gas valve illustration and gas valve, burner and orifice location when performing the following conversions. When converting from G20 to G25 gas, the following procedures apply: ¦ Equipment replacement is not required. ¦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas valve "adjustment screw". ¦ After adjustment, rep...

Dieses Handbuch ist für folgende Modelle:
Friteusen - SR42 (355.24 kb)
Friteusen - SR62 (355.24 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien