Issuing, replacing and controlling keys can be a headache for both large and small facilities. Kaba’s® Simplex® mechanical pushbutton locks eliminate those headaches by using a PIN code instead of keys for access by all authorized users. One code — that’s all you have to remember or keep up with — nothing tangible like a key or magnetic card, no batteries to replace in the lock, and no software or computers to control the lock’s operation. Simple as 1-2-3. PIN codes are made up of any combinatio
Electromagnets are not at all strong in this orientation of attack. Therefore, as the drawingshows, Securitron's Z bracket should be used with an interference piece which blocks the shearing effect while the strength of the magnet blocks one arm moving while the other is stationary. For this technique to work, the motorized operator must be coordinated which means that one arm must move first to clear the interference piece before the other arm starts moving. Gate operators can normally accompli
By 1939, ASSA had produced its first cylinder lock and delivered its first 5-pin cylinder master key system seven years later. In 1959, ASSA introduced its first registered key systems with key control. In 1981, ASSA celebrated its 100th anniversary as a company with the release of the ASSA Twin 6000 system, a new cylinder concept utilizing the dual locking mechanisms of today's ASSA cylinders. ASSA, Inc. was originally opened in Naperville, IL as a marketing arm of ASSA AB in Sweden. Incorporat
A.1, 10/99 SECURITRON MODEL LCP SERIES ELECTRIC LOCK CONTROL PANEL TABLE OF CONTENTS AND GUIDE TO THIS MANUAL The LCP series is a powerful and versatile system with many standard and optional features. You will generally use only some of these features so this table of contents includes a description of the type of application that applies to each different section. By studying it first, you can save considerable time by skipping over those parts of the manual that don't apply. SECTION 1. DESCRI
FINISHES PVD Lifetime Finish Physical Vapor Deposition (PVD) is a technologically advanced finish coating that provides the ultimate surface protection against environmental elements and everyday wear and tear. PVD matches clear coated finishes in appearance, yet surpasses them in durability. Yale® warrants all its PVD finishes against corrosion, tarnish, wear, discoloration and peeling for the lifetime of the part to which it has been applied. Ask your sales representative for specific warranty
A.1, 8/01 Page 1 SECURITRON MODEL MUNL-12, MUNL-24 MORTISE UNLATCH INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION Securitron’s Mortise UnLatch is a revolutionary new type of electric strike which eliminates the necessity to perform a routing operation on the door frame for installation. The motor driven Mortise UnLatch also presents a fully concealed appearance on the door which not only enhances architectural appeal but improves security over a conventional electric strike as an intrude
Features ¦ Programmable codes and functions include: Multi level user capability; Master code, Manager code and up to 15 user codes – group and/or individual. ¦ One-time emergency or service entrance code erases from memory after use. ¦ Timed entry allowance from 5-15 seconds. ¦ Individual, group or total user lockout code. ¦ Management can temporarily disable or permanently change any or all user codes. ¦ Easy to install. Retrofits most cylindrical locksets & digital locks. ¦ Available in stand
A.2, 10/03 D TABLE OF CONTENTS AND GUIDE TO THIS MANUAL The DK-26 is a powerful and versatile product with many features and modes of operation. In most applications you will use only some of these features so this table of contents includes a description of the type of application that applies to each different section. By studying it first, you can save considerable time by skipping over those parts of the manual that don't apply to your application. SECTION 1. DESCRIPTION --------------------
Many cylinders marketed as “high security” have no patents protecting the keys and/or cylinder and there- fore, no method for key blank control. The ASSA Twin family meets all of today’s demanding requirements of high security cylinders–uncompromising physical security and patented key control. Physical Security All Twin family cylinders are built to U.L. 437 standards, a set of tests for determining the cylinder’s physical resist- ance against various forms of attack. Two independent locking me
ASSA IC is also listed by Underwriters Laboratories and has passed the U.L. 437 test. By simply changing or reversing the ASSA IC sidebar, cylinder re-keying can be done on-site in less than 30 seconds. Therefore, the end-user is not required to stock or purchase additional spare cores. ASSA CLIQ™ Concept 4 ASSA CLIQ™ intelligent locking systems gives control over all keys, which can easily be upgraded and can be tailor-made to suit any needs. Since every key has its own identity, it becomes the