Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Heath Zenith, modell 6168

Hersteller: Heath Zenith
Dateigröße: 356.45 kb
Dateiname: 595-5724-04.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Plug wireless chime into wall outlet. Note: The volume control is on the back of the wireless chime. Unplug chime to adjust volume. To reduce the risk of electrical shock, this equipment has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not attempt to bypass this safety feature. © 2007 HeathCo LLC 595-5724-04 Installation Important considerations: Thesensor must be mountedtothe doorjamb.The magnet should be attached to the door. Sensor is for indoor use only. WARNING: To prevent possible SERIOUS INJURY or DEATH: • NEVER allow small children near batteries. • If battery is swallowed, immediately notify doctor. Use Optional Spacer if Needed Alignment Arrows 2. Install alkaline type A23 12 volt push button battery (included). Remove back of case by pushing in tab on bottom with a small screwdriver. See diagram inside sensor for correct battery orientation. 3. Select mounting location. The maximum gap between sensor and magnet is 1/2" (13 mm). The arrows located on the face of each component must be aligned and facing toward each other. The magnet must be beside the sensor. Note: If the magnet is recessed, use spacer to ensure proper alignment. 4. Test range. Before mounting, hold sensor and magnet in selected location and verify operation. While holding the sensor still, move the magnet away from the sensor to simulate door beingopened.Verifyred LED on sensorflashes momentarily and chime sounds. Note: If sensor does not operate correctly, see Troubleshooting Guide. 1/2" Maximum -2-595-5724-04 Use Optional Spacer if Needed 5. Mount sensor. Screw Mounting: Attach sensor back cover to wall using two short screws (provided). Snap sensor onto back cover. Tape Mounting: Apply foam tape to the sensor back cover. Stick sensor back cover to frame of door in desired position. Snap sensor onto back cover. 6. Mount magnet. Repeat step 5 to attach magnet (and spacer if needed) to door using two screws (provided). Note: If using spacer, use the two long screws (provided). 595-5724-04 -3 Tune Settings Your Heath®/Zenith wireless chime has different selectable tunes: Ding (one note), Ding-Dong (two note), or Westminster (eight note) (Available on selected Heath®/Zenith chimes). The factory setting is for the Ding-Dong tune (or Westminster, when available). This tune can be changed by following the instructions below. • Ding (one note tune) Sensor: Add a jumper to location 8. • Ding-Dong (two note tune) Sensor: Remove jumper from location 8. Chime: Remove jumper from location 8. • Westminster (Eight note tune) (Available on selected Heath®/Zenith chimes) Sensor: Remove jumper from location 8. Chime: Add a jumper to location 8. Note: All models have both front and back door tune capabilities.You may purchase any Heath®/Zenith wireless push button for a second entrance. 12345678 Inside Sensor Remove screw to open access door Tune Setting (Not used on all models) Tune Setting 12345678 Back of Chime Note: Some models might require the use of tweezers to remove and replace the jumpers. -4- 595-5724-04 Troubleshooting A. Chime does not sound: • Red light on the sensor does not light. Check battery polarity. Replace the sensor battery. • Red light on the sensor does light. Make sure sensor and chime codes are the same (see Code Setting below). Make sure the plug-in chime has power going to it. B. Chime sounds when not intended (false triggers): Chime is receiving interference from another wireless device; change the code setting (see Code Setting below). C. Battery seems OK, but the chime does not work when installed: • Do not mount the sensor on metal or near metal studs. This reduces the sensor range. Use 1/4" to 1/2" (6 to 13 mm) wood shims to move the sensor off the metal surface. • Concrete floors may reduce range. Move chime away from floor. • Try different locations for the chime closer to the sensor. D. Code Setting: It is recommended to only change one code position at a time and then check to see if system is functioning properly. 1. Unplug chime from power source. 2. Open the cases and locate the jumpers on both the sensor and chime. 3. The sensor and chime both have eight different jumper locations. Jumper positions 1 through 7 are used for setting the code. Continued 595-5724-04 -5 4. To change the code, either: • Add a jumper to the same location on both the sensor and the chime or... • Remove a jumper from the same location on both the sensor and the chime or... • Move a jumper on the sensor from one location to another. Move the corresponding jumper on the chime to match the new location in the sensor. Example: Move jumper at location “5” to location “4” on both the sensor and the chime. Note: Jumpers in positions 1 through 7 must be exactly the same for both the sensor and chime for this system to funct...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien