Anleitung Omega, modell RD2800

Hersteller: Omega
Dateigröße: 2.27 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


OTHER PROGRAMMING 11.5 Alarm 3 Programming Mode 1) Absolute value alarms (.,.,.,.) ........ Character display Cursor Channel Level Alarm Relay No.* Alarm value (Note) type Max. 5 digits by left-justify Unused digits are filled with spaces. (Note) Program the alarm value within the scale range. 2) Rage-of-change alarm (.,.) . ... ... . Character displayCursor Channel Level Alarm Relay No.* Alarm value (Note 1) Measuring count (Note 2) (1 to 20) type Max. 5 digits by left-justify Unused digits are filled with spaces. (Note 1) Program the alarm value with the change width (without sign) per unit time. (Note 2) Unit time = measuring interval (about 0.1 sec.) x measuring count Program this measuring count (1 to 20). 3) Differential alarm (.,.,.,.) ... ... . . Character display Cursor Channel Level Alarm Relay No.* Alarm value (Note 1) Channel to be compared (Note 2) type Max. 5 digits by left-justify Unused digits are filled with spaces. (Note 1) Program an alarm value with a difference (without sign) between measured values of channels. (Note 2) Program another channel to be compared. * In the standard specifications, the relay No. is fixed to “0” and the cursor does not appear. Program the relay No. for the alarm output (option) only. See Section 12.2. -64 11. OTHER PROGRAMMING 11.5 Alarm 4 Programming Flow Chart To delete an alarm point 1) Without alarm output (option) Follow the [Programming alarm point] procedure and select the alarm point to be deleted with/ . 0Clear it by pressing SHIFT and CLEAR simultaneously and perform [temporarily stored] and [stored] operation. Operation screen [Check] + ... ... [Programming alarm point] ..... [Selecting alarm type] > ..... [Relay No.] ..... [Selecting alarm value] ......... [Only rage-of-change alarm] > .......... [Only differential alarm] > .......... Cursor Temporarily sotred Programming other alarm points? + Stored Numeric keys Numeric keys Channel Relay No. Alarm value Level Alarm type Measuring count YES NO Channel to be compared DISP SHIFT 8 ALARM SET END %/ °F °F °F ENTRY SHIFT SET END Numeric keys Ref. 1 Ref. 2 Ref. 3 Ref. 4 Ref. 5 Ref. 6 When error appears press any key other than SHIFT 4 SCALE 1 CHART to By pressing , the level advances from 1 to 4 and the channel advances to the next channel and then the level of the next channel advances. Press for reverse operation. 1. Channel can be selected also with or . 2. Channel advances by pressing . Then “FaiL” and “C.End” appear but these functions are only available in the alarm output (option). Relay No. is fixed to “0” and no cursor appears as the alarm output (option) is not added. The relay No. for AH is displayed with 2 digits of “00”. Programming range is 1 to 20. Reference channel to be compared is programmed in 1 to 4. (The differential alarm cannot be selected in a 1-pen type recorder because no channel to be compared is existed.) Store the [temporarily stored] parameters into the memory. (A programming change mark is printed.) / % Storing Reference 6 Other alarm point check Reference 1 Programming alarm point Reference 2 / % / Relay No.Reference 3 Cursor appears only for rate-of-change alarm. Reference 4 Cursor appears only for differential alarm. Reference 5 -65 11.OTHER PROGRAMMING 11.5 Alarm 2) With alarm output (option) Operation screen [Output check] + ..... [Programming check] ... [To be ready for programming] ... [Programming alarm point] ..... [Selecting alarm type] > ..... [Programming relay No.] ..... [Programming alarm value] ......... [Only rate-of-change alarm] > .......... [Only differential alarm] > .......... Cursor Temporarily stored Programming other alarm points? + Stored Follow the [Programming alarm point] procedure and select the alarm point to be deleted with . Clear it by pressing and simultaneously and perform [temporarily stored] and [stored] operation. The relay Nos. in alarm output are displayed. This will be blank unless all of the relays are operated. By pressing , the level advances from 1 to 4 and the channel advances to the next channel and then the level of the next channel advances. Press for reverse operation. 1. Channel can be selected also with or . 2. Channel advances by pressing Then “FaiL” and “C.End” appear. If these functions are selected, program relay Nos. only. This is for specifying terminal Nos. for alarm output. The relay No. for AH is displayed with 2 digits such as “00”. See Section 12.2.When programming “1” to “9”, two entering methods of 1 to 9 or 01 to 09 are available. ( : space) Programming range is 1 to 20. Reference channel to be compared is programmed in 1 to 4. (The differential alarm cannot be selected in a 1-pen type recorder because no channel to be compared is existed.) Store the [temporarily stored] programmed values into the memory. (A programming change mark is printed.) Numeric keys Numeric keys Channel Relay No. Alarm value Level Alarm type Measuring count YES NO Channel to be compared Relay No. DISP SHIFT 8 ALARM ENTRY SET END %/ ...

Dieses Handbuch ist für folgende Modelle:
DVD-Player - RD200 (2.27 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien