Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Hitachi Koki USA, modell DV 18DL

Hersteller: Hitachi Koki USA
Dateigröße: 2.98 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


. When the battery is fully charged, the pilot lamp will bilink in red slowly. (At 1-second intervals) (See Table 2) Table 2 Lamp indications Indications of the pilot lamp Charge status lamp (RED) Before charging Blinks (RED) Lights for 0.5 seconds. Does not light for 0.5 seconds. (off for 0.5 seconds) While charging Lights (RED) Lights continuously Charging complete Blinks (RED) Lights for 0.5 seconds. Does not light for 0.5 seconds. (off for 0.5 seconds) Charging impossible Flickers (RED) Lights for 0.1 seconds. Does not light for 0.1 seconds. (off for 0.1 seconds) Malfunction in the battery or the charger Overheat lamp (GREEN) Overheat standby Lights (GREEN) Lights continuously Battery overheated. Unable to charge (Charging will commence when battery cools). NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan. English . Regarding the temperature of the rechargeable battery The temperatures for rechargeable batteries are as shown in the table below, and batteries that have become hot should be cooled for a while before being recharged. Table 3 Recharging of batteries that have become hot Rechargeable batteries Temperatures at which the battery can be recharged EBM1830 32°F—122°F (0°C—50°C) 4. Disconnect battery charger from the receptacle CAUTION: Do not pull the plug out of the receptacle by pulling on the cord. Make sure to grasp the plug when removing from receptacle to avoid damaging cord. 5. Remove the battery from the battery charger Supporting the battery charger with hand, pull out the battery from the battery charger. CAUTION: . Repair is required if the receptacle is not secured properly or the power cord does not stay in the receptacle. Consult your electrician. Using the charger in this condition may lead to fire. . If the charge status lamp is blinking orange rapidly (in 0.2 second intervals) and the buzzer sounds intermittently for 5 seconds, check that the hole for connecting the battery is not obstructed. Remove any obstructions. If no obstructions are found, the battery or charger may be malfunctioned. Return both to your place of purchase. . If the charge time lamp does not light when the power cord is connected to the receptacle, disconnect the power cord, and check that the battery is attached correctly. . The battery retains heat when used or left for prolonged periods in direct sunlight. In this state, the charge time lamp flashes red, and the battery cannot be charged immediately. Leave the battery inserted in the charger, and charging will commence when the battery cools down. . If the lamp goes out while charging, disconnect the power cord, and leave for 3 to 5 minutes before reconnecting. If the problem persists, call for repairs. . Leave 5 minutes between charging batteries as the charger may overheat leading to malfunction. . The battery life is finished if it can only be used for short periods even when fully charged. Purchase a new battery. Continuing to use a depleted battery may cause the charger to malfunction. NOTE: . Charging times may be longer depending on the surrounding temperature and battery conditions. . Charge time lamp indications are only a guide, and may vary depending on the surrounding temperature and battery conditions. . Remove the battery from the charger when not in use. English Revitalizing the battery (trickle recharge) A new battery or a battery that has not been used for extensive periods may not charge completely due to internal chemicals being inert. Leave the battery inserted in the charger for 8 to 12 hours after charging is complete. The charger automatically “revitalizes” the battery by trickle recharging. How to make the batteries perform longer (1) Recharge the batteries before they become completely exhausted. When you feel that the power of the tool becomes weaker, stop using the tool and recharge its battery. If you continue to use the tool and exhaust the electric current, the battery may be damaged and its life will become shorter. (2) Avoid recharging at high temperatures. A rechargeable battery will be hot immediately after use. If such a battery is recharged immediately after use, its internal chemical substance will deteriorate, and the battery life will be shortened. Leave the battery and recharge it after it has cooled for a while. BEFORE USE Check the work area to make sure that it is clear of debris and clutter. Clear the area of unnecessary personnel. Ensure that lighting and ventilation is adequate. OPERATION 1. Using the light equipped hook WARNING: When using the hook, pay sufficient attention so that the main equipment does not fall. If the tool falls, there is a risk of accident. CAUTION: . Do not attach the tip tool except phillips bit to the tool main unit when carrying the tool main unit with the hook suspended from a waist belt. Injury may result if you carry the equipment suspended from the waist belt with sharp tipped components such as drill bit attached. English 1.1 Using the ...

Dieses Handbuch ist für folgende Modelle:
Bohrmaschinen und Schrauber - DS 18DL (2.98 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien