7 Electrical Connection This appliance should be properly grounded for your safety. The power cord of this appliance is equipped with a three-prong plug which mates with standard three prong wall outlets to minimize the possibility of electrical shock. Plug the appliance into an exclusive properly installed-grounded wall outlet. Do not under any circumstances cut or remove the third (ground) prong from the power cord. Any questions concerning power and or grounding should be directed toward a certified electrician or an authorized Avanti Products service center. This appliance requires a standard 115/120-volt. 60Hz electrical outlet with three-prong ground. The cord should be secured behind the appliance and not left exposed or dangling to prevent accidental injury. Do not use an adapter plug with this appliance. Do not use an extension cord with this appliance. If the power cord is too short, have a qualified electrician or service technician install an outlet near the appliance. Control and Display Panel For operation of unit, please fill water and make sure water settles inside the water tank, and then switch on both hot and cold switches at back of unit. Working Programs: Energy Saving Program: When the PROGRAM button is pushed down, it’s under Energy Saving Program; The (green) E-S indicator will be displayed. During operation the (red) “WARM” cycle indicator will be displayed until the temperature of the water in the reservoir reaches 60.C/140.F. Once the temperature reaches 60.C/140.F (approximately 4 minutes) the (red) “WARM” indicator will turn off and will remain off until the temperature of the water in the reservoir drops to 50.C/122.F at which time the (red) “WARM” cycle indicator will turn on and the cycle will start again. 8 During “Energy Saver” Program, when you press the “HOT WATER” button, the (red) “HOT” cycle indicator will be on and water temperature in the reservoir will be heated to 90.C/194.F (approximately 4 minutes). Once the water temperature reaches 90.C/194.F the (red) “HOT” cycle indicator will turn off and will remain off until the “HOT WATER” button in pressed again. Normal Program: When the PROGRAM button is released, it’s under Normal operation mode and the (orange) NORM indicator light will displayed. During operation the (red) “HOT” cycle indicator will be on until the temperature of the water in the reservoir reaches 90.C/194.F (approximately 9 minutes). The (red) “HOT” cycle indicator will turn off and will remain off until the temperature of the water in the reservoir drops to 81.C/178.F at which time the (red) “HOT” cycle indicator will turn on and the cycle will start again. When the unit is in “NORMAL PROGRAM” the “HOT WATER” button is non-functional. Cold Temp (Energy Saver / Normal Modes): The cold water cycle is not affected by either program and continuously runs to maintain a cold water temperature between 5.C/41.F and 10.C/50..F. Once the “Cold Switch” at the rear of the unit is turned ON the (blue) “COLD” cycle indicator will be on until the temperature of the water in the reservoir drops to 7./44.F or less, the (blue) “COLD” cycle indicator will turn off and the cooling cycle will stop until the temperature reaches 10/50.F, at which time the (blue) “COLD” cycle indicator will turn on again and the cooling cycle will start again. Light: When the light button is pushed, the light will turn on. Pushed again, the light will turn off. NOTE: THE HOT WATER FAUCET HAS A CHILD-SAFETY GUARD ATTACHMENT. To get hot water: ¦ Slide red safety button to the right and hold while pressing downward on hot water faucet to dispense hot water. ¦ Safety button will return to its original position when faucet is released. Cup Dispenser (OPTIONAL) The cup dispenser may be installed by using the mounting holes (covered with plastic caps) located near the top of the right side panel of the cooler. The cup dispenser comes equipped with a mounting bracket and screws and may be ordered by completing the enclosed order form provided with your instruction manual. CARE AND MAINTENANCE • Wash the inside of the reservoir with a warm water and baking soda solution. The solution should 9 be about 2 tablespoons of baking soda to a quart of water. (Turn off the hot water function). • The drip tray and water faucets should be cleaned with mild detergent and warm water. • At regular intervals or once a month inspect the coils located across the back of the dispenser. Vacuum accumulation of dust or clean it with a hard brush. TAKING DISPENSER OUT OF SERVICE • If the water dispenser will not be used for a long period of time, unplug the power cord from the wall outlet. • Turn off the hot water. • Drain the water through the faucets. • Drain the water from the tanks by removing the plug from the back of the dispenser. WARNING—THE WATER COMING OUT OF THE BACK MAY BE SCOLDING HOT. • Unit should NOT be transported on the units side. Place it upright if possible and cover it with a blanket. PROBLEMS WIT...