Login:
Stimmen - 5, Durchschnittliche Bewertung: 4.4 ( )

Anleitung Anetsberger Brothers, modell FFM-150

Hersteller: Anetsberger Brothers
Dateigröße: 90.26 kb
Dateiname: e6bd8cbf-5d64-47d4-ac40-4d80c0a6d7ff.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


WARNING Only use filter paper envelopes from Anetsberger Brothers that have been specifically designed for this filter system. Using the wrong type of filter paper can cause damage to the pump system, and will void the Warranty ! DANGER ! Make sure the filter pan has cooled completely to room temperature before attempting to change the paper. 1. Unplug the cord from the receptacle. 2. Disconnect the line from the pump to the filter screen. 3. Remove the filter cover. 4. Remove the filter screen assembly from the filter pan and place on a clean surface for disassembly. 5. Detach quick-connect coupling on drain tube from knurled retaining nut. 6. Detach knurled retaining nut from fitting in screen. 7. Remove filter envelope clip from end of filter screen and folded back end of envelope. 8. Remove filter envelope from filter screen. WARNING The oil soaked filter envelope may still be very hot and could cause burns. 9. Clean the filter pan, filter screen and all components thoroughly using a solution of hot water and detergent. Make sure that all food and breading particles are removed from the pan and from the filter screen. 10. Dry the pan, the screen and all components completely before starting to reassemble. 11. Follow instructions under FILTER UNIT PREPARATION to install new filter envelope. FIL FILFILFILFILFILTER SY TER SYTER SYTER SYTER SYTER SYSTEM STEMSTEMSTEMSTEMSTEM TR TRTRTRTRTROUBLESHOO OUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOOUBLESHOOTING GUIDE TING GUIDETING GUIDETING GUIDETING GUIDETING GUIDE PROBLEM SOL SOLSOLSOLSOLSOL UTION UTIONUTIONUTIONUTIONUTION Pump does not 1. Make sure the power cord is plugged into the proper 120 Volt receptacle. i start when the 2. Turn the switch on the front of the filter to “ON”. switch is activated. 3. If the pump still hasn’t started, depress the thermal overload button on the bottom of the motor. If the motor is hot to the touch, wait at least 15 minutes before trying this. 4. If the pump starts and stops again in a short time, or if it hums but does not pump, there is a restriction somewhere in the filter screen or in the pump itself. Go to Step 5. If there is no reaction from the pump, go to step 6. 5. Allow the oil/shortening in the filter pan to cool, then empty the pan and verify that the filter paper and screen assembly is assembled correctly. Disassemble the filter screen and look for blockages of sediment or solid shortening within. 6. Problem is with the motor/pump or the wiring. Remove the motor from the filter and bench test by connecting a 120V line to the motor leads. If it runs, the problem is with the wiring between the motor and the power supply. If it does not run, the motor needs to be replaced. Filtering procedure is 1. If solid shortening is being used allow HOT oil to recirculate through the lines very slow. Shorten-long enough to ensure that all solidified shortening has melted. ing/oil returning to the 2. After all the shortening/oil has been pumped back into the fryer, inspect the fryer very slow. filter paper envelope. Make sure that any excess sediment is removed from the top of the filter paper envelope. 3. If the filter paper envelope is dirty or torn, disassemble the filter screen assembly. Inspect for blockages in the lines. Replace with a clean filter paper envelope. WARNING Only use filter paper envelopes from Anetsberger Brothers that have been specifically designed for this filter system. Using the wrong type of filter paper can cause damage to the pump system, and will void the warranty. 3. If the oil still returns to the fryer slowly, the problem may be a blockage within the pump itself. The pump section of the motor can be easily disassembled to look for blockages of sediment or solid shortening within. LIMITED WARRANTY ANETSBERGER BROTHERS, INC., Northbrook, Illinois, USA, certifies that all equipment of its manufacture is, to the best of its knowledge, free from defective material and workmanship. ANETSBERGER BROTHERS, INC., agrees to replace any integral part of its equipment that proves defective within 15 months of date of original shipment from the factory, or 12 months from the date of installation, whichever is sooner. Buyer must return the defective part to the factory, freight prepaid, for inspection. Anetsberger Brothers, Inc., further agrees to assume the cost of installing said replacement part within the same period. Overtime charges, calibration, adjustments and abnormal installation charges shall not be at the expense of Anetsberger Brothers, Inc. The conditions and warranty expressed above are valid only if equipment has been properly installed and operated. No other warranty, expressed or implied, shall govern equipment manufactured by Anetsberger Brothers, Inc. Under no circumstances shall Anetsberger Brothers, Inc., be liable for loss of profits or any direct or indirect cost, expenses, loss or damages arising out of defects in or failure of the equipment or any part thereof. Anetsberger Brothers, Inc. 180 No...

Dieses Handbuch ist für folgende Modelle:
Dispenser - FFM-80 (90.26 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien