Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Nuvo, modell 110

Hersteller: Nuvo
Dateigröße: 3.83 mb
Dateiname: f5147a33-fc37-4ff2-a446-27879c5867db.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


(See troubleshooting for details.) G. Always remove all bottles before relocating your wine cellar. HARDWARE KIT C B A Cam Cap x 20 (x24)* Hex Wrench x 1 Hex Bolt x 14 D F E Leg x 4 Cam x 20 (x24)* Cam Pin x 20 (x24)* H G In Cooling Unit Box Hex Bolt (Flange) x 2 Panel Insulation Strip x 1 *NOTE : Hardware quantities for Model 220 are indicated in parenthesis. STEP 1 : PANEL PREPARATION CAUTION : 1. Watch for sharp staples on boxes. 2. DO NOT STEP ON PANELS 3. The manual will give a recommended order to open boxes, it saves space and time. PANEL EDGE H H H 1 Open Box VP1. Install INSULATION STRIP (H) to Back, Top, and Bottom Panels. PUSH IN FULLY! Insert Cam Pins (E) by hand in BACK PANEL’S predrilled holes down to TAB.(May require some force) H 1 2 ! CAUTION : DO NOT BREAK CAM PIN TABS! DO NOT HAMMER! TAB TAB BACK PANEL E STEP 2 : CABINET ASSEMBLY 1 Attach Top and Bottom to Back by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! Insert Cam, push all the way in under panel level (may require some force) and make sure Arrow points to outside edge, use allen key provided or #3 phillips screwdriver. Cam Arrow faces away from outside edge when tightened 2 METAL 2 2 1 PANEL EDGE CAM in LOCKED POSITION METAL BOTTOM PANEL ........ STEP 2 : CABINET ASSEMBLY CONTINUED Open Box VP5 or VP2. Insert Cam Pins (E) into SIDE PANEL’S predrilled holes both sides down to TAB. (May require some force) Attach SIDES to Back/Bottom/Top by Carefully aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. CHECK PANEL ORIENTATION !!! Insert Cam and make sure Arrow points to outside edge, use allen key provided or #3 phillips screwdriver. Start locking one cam at each end first. Lock all Cams. Cam Arrow faces away from outside edge when tightened. 1 2 ........ 1 E CHECK PANEL ORIENTATION !!! TOP !!! 2 HOLES FOR MODEL 110 2 3 HOLES FOR MODEL 220 BOTTOM PANEL ........ Place cabinet against a wall to push sides in place. A ........ 3 3 Insert Cam Cap (A) in all Cam Holes. STEP 3 : HINGE,BASE AND LEGS INSTALLATION Open Box VP3. Fasten one HINGE (found in door box) to the SIDE of the cabinet with Hexbolts (B). NOTE : Fasten BASE to the BOTTOM of the cabinet (FRONT BASE has to be set with Base Tabs 1 F Hinge can be on either side of the cabinet. 2 Install four LEGS (F) into BASES fully in. F B 3 3 FRONT BASE 4 Fasten BASE with HEX BOLTS (B) 1 3 B CABINET BOTTOM 4 C 5 5 Raise cabinet and check for potential air leaks at panel joints from inside. NOTE: Fasten base with base tab away from the front edge, then fasten and adjust the hinge before fully tightening HEX BOLTS (B) STEP 4 : SHELVES 1 Open box VP4 Hook SHELVES into hangers starting from the bottom of cabinet HINT : CENTER SHELVES ON HANGERS PRESS 1 TOP 1 2 BOTTOM 1 Snap SHELVES into hangers on one side 2 Push the SHELVES down to snap into opposite side hangers CABINET BOTTOM STEP 6 : LIGHT AND LIGHT COVER INSTALLATION 1 Plug cord to LIGHT 2 Insert LIGHT to LIGHT COVER 3 Insert LIGHT COVER to holes pre drilled on front edge of TOP panel. STEP 7 : DOOR INSTALLATION Insert DOOR onto BOTTOM HINGE 1 1 C 2 B 2 Install TOP HINGE with HEX BOLTS (B) NOTE : Adjust final position of the door before tightening the bolts and move cellar into place, leaving 4” clearance all around cellar. MAKE SURE CABINET IS AIRTIGHT! Adjust the level by turning (counter clockwise) the LEGS (F) as needed. Use a carpenter’s level. F CONTROLS : PLUG IT IN (wait one minute) and ENJOY! FEATURES: - Default SET temperature 57. F/14. C (ideal for wine storage). - Calibration option of the temperature sensor. - Display of actual temperature by request. - SET temperature range 52.F-64.F. - Digital temperature sensor. - Dual display F./C.. - Settings are stored in memory for power failures. - Pre programed software will reach the quietest most efficient operation. OPERATION: - The display will show the detected temperature until the temperature will fall within 3. of the SET POINT. - If the temperature is above the default 57. F + 1. or other preset value, after a delay of 1 minute the fan will start, followed by the compressor within the next minute. - The unit will cycle ON/OFF based on the temperature reading. Fan speeds are automatically set by the controller to achieve optimum performance. - Minimum ON and OFF cycle times are imposed by software, to prevent "short cycling". SAFETY FEATURES: ALARM: - If the temperature exceeds 72. F the unit will shut down, a sound warning will start and the dispaly will blink alternating with the temperature reading. - This function is disabled in the first 4 hours “ Cool Down” period or after any reset for another 4 hours. - The unit will restart and continue the cooling and cycling if the temperature falls below 72. F. TO RESET: - Unplug and re plug the unit. DISPLAY: KEYS 57 DISPLAY EXAMPLE CONTROLLER OPERATION ACTION BEFORE AFTER Actual temperature: PRESS SET tempe...

Dieses Handbuch ist für folgende Modelle:
Dispenser - 220 (3.83 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien