Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Nuvo, modell 250

Hersteller: Nuvo
Dateigröße: 4.76 mb
Dateiname: 38da0092-c861-41dc-abc2-cc028d18e4dd.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


AREA FOR ASSEMBLING YOUR WINE CELLAR Choose a clear 12’ by 12’ area with a level floor and carpeting to help reduce scratching of surfaces. 3. TOOLS * Hex wrench (included) * Phillips screwdriver * Carpenter’s level * Helper or two is strongly recommended 4. TEST THE COOLING UNIT Plug it in for a few minutes on a table top, to verify that controls and display are functional, and that the unit is producing cool air after a few minutes of operation. Note that the electronic controller has a one-minute cautionary delay between initial plug-in and start-up of the compressor. NOTE: Fill out the WARRANTY REGISTRATION FORM with the serial number located on the LEFT SIDE of unit. A. Provide 4” minimum clearance for both sides and back, keep the top completely clear. Under no circumstances should the unit be “built-in” in any way. B. Never locate your wine cellar outdoors or in an area with extremes of temperature and humidity. Garages, attics, unfinished basements, laundry rooms, breezeways, closets, bedrooms or any unventilated room. In other words these units must be installed in air-conditioned environments which do not “trap” the warm air being exhausted. C. Temperatures in surrounding area must not exceed 80 °F (25 °C) with humidity levels not to exceed 70% R.H. (Relative Humidity). Never set your temperatures below default (57.F) whenever ambient conditions are warm (above 75.F) or humid (above 50%R.H.). D. Outlet power must be a DEDICATED separately fused, grounded, 15 Amp 110 - 120 V line or 7.5 Amp - 240 V line rated for your unit (CHECK BOX OR SERIAL NUMBER LABEL ON UNIT FOR YOUR LINE VOLTAGE REQUIREMENTS). E. You must monitor your unit DAILY. If unit is in “Alarm”, unplug the unit inmediately. Always check for any water (condensate) leaks. Vintage Keeper will not be liable or responsible for incidental or consequential damages. (See Warranty). F. Place unit in a clean area and allow access to the exterior surfaces for periodic vacuuming of the condensor coil. (See troubleshooting for details.) G. Always remove all bottles before relocating your wine cellar. HARDWARE KIT Cam Cap x 26 (x30)* Hex bolt x 22 (x30)* Coupler screw x 8 Hex wrench x 1 Cam x 24 (x28)* Cam Pin x 24 (x28)* Coupler hanger x 4 Hinge x 4 In Cooling Unit Box Hex Bolt (Flange) x 2 Panel Insulation Strip C B A D F G E H J I *NOTE : Hardware quantities for Model 500 are indicated in parenthesis. STEP 1 : PANEL PREPARATION CAUTION : 1. Watch for sharp staples on boxes. 2. DO NOT STEP ON PANELS 3. The manual will give a recommended order to open boxes, it saves time and space. PANEL EDGE J J J Open Boxes VP6 and VP7. Install INSULATION STRIP (J) to Back, Top, and Bottom Panels. PUSH IN FULLY! Insert Cam Pins (F) in BACK PANEL’S predrilled holes down to TAB. (May require some force) J 1 2 ! CAUTION : DO NOT BREAK CAM PIN TABS! DO NOT HAMMER! TAB TAB BACK PANEL F C 3 3 Screw in both screws (C) half way in Coupler Hanger (G) to back panels and tighten fully when both screws are in. G STEP 2 : CABINET ASSEMBLY METAL 2 PANEL EDGE CAM in LOCKED POSITION METAL Use allen key provided or #3 phillips screwdriver. BOTTOM PANEL 1 Attach TOP and Bottom to Back by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! Insert Cam, push all the way in under panel level (may require some force) and make sure Arrow points to outside edge. Gently push down to bring panels together before you tighten the Cam. Start with cams at each end. Cam Arrow faces away from outside edge when tightened. ........ 2 3 Insert Center COUPLER BAR by guiding edge holes over bottom Cam Pins. Lightly push out top panel edge to allow Cam Pins to go in Coupler Bar. Insert and tighten Cams. BOTTOM PANEL 3 COUPLER BAR INSIDE CABINET STEP 2 : CABINET ASSEMBLY CONTINUED Open Box VP5 or VP2. Insert Cam Pins (F) in BACK PANEL’S predrilled holes down to TAB. (May require some force) Attach SIDES to Back/Bottom/Top by CAREFULLY aligning edge holes over Cam Pins and gently push together to avoid damaging cam pins. DO NOT BANG OR SLAP PANELS TOGETHER!!! Insert Cam, push all the way in under panel level (may require some force) and make sure Arrow points to outside edge., Push Panels together before tightening Cam, use allen key provided or #3 phillips screwdriver. Start with cams at 1 2 TOP !!! 2 HOLES FOR MODEL 250 F 3 HOLES FOR MODEL 500 BOTTOM PANEL 3 ........ A 3 Insert Cam Cap (A) in all Cam Holes. STEP 3 : HINGE,BASE AND LEGS INSTALLATION Open Box VP3. Fasten one HINGE (found in door box) to the SIDE of the cabinet Install four LEGS (H) into BASES fully in. Fasten FRONT BASE to the BOTTOM of the cabinet (FRONT BASE has to be set with end tabs away from front edge) Fasten BASE with HEX BOLTS (B) 2 1 H 2 3 H 4 H 1 4 BOTTOM OF CABINET B 3 D 1 5 NOTE: Fasten base with base tab away from the front edge, then fasten and adjust the hinge before fully tightening HEX BOLTS (B) 5 Raise cabinet and check for potential...

Dieses Handbuch ist für folgende Modelle:
Dispenser - 500 (4.76 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien