Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Bunn, modell AFPO-2

Hersteller: Bunn
Dateigröße: 841.66 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The mating connector must be a NEMA 5-15R. The 230 volt CE version requires 2 wire, grounded service rated 230V ac, single phase, 50 Hz. The 200 volt or 240 volt versions require 2 wire, grounded service rated 200 volts ac or 240 volts ac, single phase, 50 Hz. (Refer to the dispenser’s data plate for exact voltage requirement.) CE REQUIREMENTS • This appliance must be installed in locations where it can be overseen by trained personnel. • For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C. • Appliance shall not be tilted more than 10° for safe operation. • An electrician must provide electrical service as specified in conformance with all local and national codes. • This appliance must not be cleaned by water jet. • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of this appliance by a person responsible for its safety. • Children should be supervised to ensure they do not play with the appliance. • If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard. • Machine must not be immersed for cleaning. 28791 071411 Electrical Hook-Up CAUTION – Improper electrical installation will damage electronic components. 1. An electrician must provide electrical service as specified. 2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source. 3. Connect the dispenser to the power source. PLUMBING REQUIREMENTS This dispenser must be connected to a cold water system with operating pressure between 20 and 90 (138 and 620 kPa) psi from a 1.2” or larger supply line. A shut-off valve should be installed in the line before the dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water inlet fitting is 1.4” flare. NOTE - Bunn-O-Matic recommends 1.4” copper tubing for installations of less than 25 feet and 3.8” for more than 25 feet from the 1.2” water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the countertop. Tubing is supplied by Bunn-O-Matic (part number 00326-0000). Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the hole made in the supply line by this type of device may restrict water flow. INITIAL SET-UP NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time. NOTE: Hoses and product container connectors are not supplied. Fitting, clamps and labels are supplied. Make hose assemblies as required. Refer to PIPING DIAGRAM on page 23. 1. Assemble hoppers with probe housing assemblies to dispenser or modify existing hoppers using template provided. 2. Make sure probe housing assembly is pushed down into slots on back of hoppers. 3. Install cable assembly to the lower right front of the auto refill box and the probe housing assemblies on the hoppers. The connectors on the cable pushes in and cap rotates 1/4 turn to lock into position. 4. Run output tubes from auto refill box to the quick disconnects in the hoppers. NOTE: Make sure numbers on the labels match up. Cable#1 with Hose#1, Cable#2 with Hose#2,....etc. As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate backflow prevention to comply with federal, state and local codes. For models installed outside the U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area. NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and maintained in accordance with federal, state and local codes. 28791 071411 5. Connect one end of input hoses to the auto refill box and the other end to the product container. Product container connectors (BIB) are not supplied. Install your own interface. 6. Connect water line to auto refill box. A minimum of 20 psi (138 kPa) is required. NOTE: Make sure all connections are made before connecting the auto refill box to the power source. 7. Each product container has an ON/OFF refill switch located on the front of the auto refill box. A second switch for each hopper is at the probe housing assembly. These are 3 position switches, high level, low level and a center “OFF” position. 8. Place the main ON/OFF switch and ON/OFF refill switches in the “OFF” position. 9. Make sure all hoses are conn...

Dieses Handbuch ist für folgende Modelle:
Dispenser - AFPO-3 (841.66 kb)
Dispenser - AFPO-2 SL (841.66 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien