Anleitung Zusammenfassung


Wet Tap Assembly: Provides a safe and fast method of removing a flow sensor element without shutting off flow and pressure. (Maximum Pressure – 100 psig @ 680F; Maximum Temperature – 140°F @ 25 psig) High Temperature/Pressure Applications: Contact factory for pressures up to 1,500 psig and temperatures up to 300°F for stainless steel flow sensors. ** Threaded Tee Sch 40 Galv. Pipe Flow Rate Range Table *** Cast Iron Saddle Sch 40 Pipe Installation Fitting Pipe Size – (Inches) Cv Factor Flow Rate Range – (GPM) Minimum Maximum 1 ** 39.0 0.7 44.0 11/4 ** 56.0 1.2 80.0 11/2 ** 84.0 1.7 110.0 2 ** 157.0 2.8 187.0 21/2 *** 273.0 4.5 298.0 3 *** 483.0 6.9 460.0 4 *** 977.0 11.9 793.0 5 *** 1750.0 18.7 1247.0 6 *** 2846.0 27.0 1800.0 8 *** 5773.0 47.0 3118.0 10 *** 10,660.0 74.0 4915.0 Choose the Installation Fitting Pipe Size principally on the MINIMUM flow rate that would occur REGULARLY in the treated water stream of each water treatment tank. DO NOT OVERSIZE THE INSTALLATION FITTING! C= flow rate (GPM) @ 1.0 psi head loss; 60°F water temperature. V includes worst case requirement of 50 pipe diameters before and 5 pipe diameters (following the flow sensor location assuring minimum flow turbulence. Specifications Pressure Loss @ maximum rated flow: Less than 3.5 psig. See formula † • includes head loss of required straight length of pipe both before and after flow sensor location.(maximum requirement –55 diameters) CFactor: See Flow Range V Table Flow Rate Range: 0.3 thru 20 feet per second fluid velocity Output Linearity: ± 1% of maximum range Accuracy: ± 1% of maximum range Repeatability: ± 0.5% of full range Wetted Materials: Polypropylene, Viton, Titanium, PVDF *Maximum Temperature: 185°F @ 25 psig *Maximum Pressure: 180 psig @ 680F Installation Requirements: *Maximum wire length 200 ft. –contact between sensor and factory for greater IQS/3 Controller distance requirements *Number of pipe diameters required adjacent to flow sensor location dependent on source of upstream turbulence: Electrical Output: *Requires DC Current from IQS/3;+5VDC @ 10 ma. Environmental: Ambient temperature Relative Humidity: Dimensions: X: 1/2" thru 4" = 3.50" 5" thru 8" = 5.00" 10" up = 7.75" ) 15 minimum/ 55 maximum Open Collector, transistor, sinking -40F to 1220F 0% to 100% Non-condensing *Refer to table for temperature/pressure/ installation fitting relationships. TM Commercial Systems ©2000 Culligan International Co. 1-800-CULLIGAN DCO 992196 Printed in USA 01/00 SL-0064 Moore Part No. 49004 Limited WARRANTY Culligan® Hi-Flo® 2 and 2e Series, Hi-Flo® 52 series, Hi-Flo® 42 Series, Hi-Flo® 55e Series, CSM Series and Hi-Flo® 50 Series You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, this product is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of o...

Dieses Handbuch ist für folgende Modelle:
Dispenser - HD-202 (2.25 mb)
Dispenser - HD-604 (2.25 mb)
Dispenser - HD-726 (2.25 mb)
Dispenser - HD-846 (2.25 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien