Login:
Stimmen - 3, Durchschnittliche Bewertung: 3 ( )

Anleitung Kenwood, modell DPF-R6030

Hersteller: Kenwood
Dateigröße: 695.39 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
CD-Player - DPF-R6030 (398.74 kb)ru

Anleitung Zusammenfassung


(2) to the shape of the wall outlet. (Except for CD-403/DPF-R3030) (Except for CD-403/DPF-R3030) (Accessory only for regions where use is necessary.) REMOTE CONTROL UNITRC-P0601 POWER 1 2 DOWN UP 3 4 5 6 7 8 9 P.MODE 0 +10 TIMEDISP. CLEAR CHECK SKIPREPEAT RANDOMEDIT DISCSELECTOROUTPUT 54312 Special features CD-TEXT support (CD-406/DPF-R6030 only) Advanced technologies incorporated in pursuit of improved sound quality and stability (CD-406/DPF-R6030 only) Convenient features for dubbing CD onto tape Easy operation functions ¶ The text information such as disc title or track title (up to 1000 letters) recorded on the CDs can be easily called and displayed in alphanumerics. (Some words and text may not be displayed.) @ ¶ D.R.I.V.E. (Dynamic Resolution Intensive Vector Enhancement) IC is built in for drastic reduction of distortion at small signal level. ¶ Edit mode is the function for rearranging tracks according to the tape length so that no music is interrupted in the middle. ( ¦ Auto space function. % ¶ Easy operation functions allow systematic operation with other KENWOOD components connected through the system control connection. 5 As an ENERGY STAR® Partner, Kenwood Corporation has determined that this products meets the ENERGY STAR® guidelines for energy efficiency. This product can save energy. Saving energy reduces air pollution and lowers utility bills. Caution: Read the pages marked carefully to ensure safe operation. Contents Before applying power................................................... 2 Safety precautions ...................................................... 2 Unpacking .................................................................... 3 Special features ........................................................... 3 System connections ....................................................... 4 Controls and indicators.................................................. 6 Operation of remote control unit ................................. 8 Preparing to play tracks ................................................. 9 Normal play (TRACK mode) ........................................ 10 Displays.......................................................................... 12 Programmed play (PGM mode) ................................... 13 Playback in a random order (Random playback) ....... 16 Repeated playback ........................................................ 17 Editing ............................................................................. 19 Timer operations ........................................................... 21 Maintenance ................................................................... 22 In case of difficulty ........................................................ 23 Specifications ................................................................. 24 System connections Caution: Do not plug in the power lead until all connections are completed. SYSTEM CONTROL DIGITAL OUTPUT LINE OUTPUT VARIABLE OPTICAL R L TEXT SYSTEM CONTROL DIGITAL OUTPUT LINE OUTPUT VARIABLE COAXIAL OPTICAL R L L R CD SYSTEM CONTROL OPTICALCOAXIAL DIGITAL INPUT TEXT If operation is not possible or erroneous display appears even though all connections have been made properly, reset the microcomputer referring to “In case of difficulty”. . Make connections as shown below. When connecting the related system components, refer also to the instruction manuals of the related components. Malfunction of microcomputer 75W coaxial cable with RCA PIN. (Commer- cially-available) Remove the protection cap when using the DIGITAL OUTPUT (OPTICAL) jack (OPTICAL) DIGITAL INPUT (COAXIAL) Digital component (MD, DAT, etc.) System control cord Commercially-available optical fiber cable Amplifier (or receiver, etc.) Audio cord To wall AC outlet To wall AC outlet CD-406/DPF-R6030 : CD-404/403/ DPF-R4030/R3030 : DIGITAL INPUT (OPTICAL) Remove the protection cap when using the DIGITAL OUTPUT (OPTICAL) jack Connection to digital amplifier or MD Connect the DIGITAL OUTPUT (OPTICAL or COAXIAL (CD-406/DPF-R6030 only)) jack to the digital input jack of the amplifier, DAT recorder, MD recorder, etc., using an optical fiber cable or coaxial cable which are commercially available in audio stores. OWhen using an optical fiber cable to connect this unit to a digital amplifier, insert the plug straight into the jack until a snap sound is heard. OBe careful not to bend, coil, or bundle the optical fiber cable. OOptical fiber cables available on the market may not always be able to be used with this player. If your cord cannot be used with this unit, consult the store from which you purchased the cord or your nearest dealer. Optical fiber cable NotesNotes 1. Connect all cords firmly. If connections are loose there could be loss of sound or noise produced. 2. When plugging and unplugging connection cords, be sure to first remove the power cord from the AC outlet. Plugging/unplugging connection cords without removal of the power cord can ...

Dieses Handbuch ist für folgende Modelle:
CD-Player - CD-403 (695.39 kb)
CD-Player - CD-404 (695.39 kb)
CD-Player - CD-406 (695.39 kb)
CD-Player - DPF-R3030 (695.39 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien