Anleitung Zusammenfassung


To turn OFF the COLD timer, press the “AUTO TIMER” clock button(s) until the light(s) on the clock button(s) turns off. Operate in Automatic Mode (with COLD Timer Activated) 1. Turn power switch ON and wait for LED display to light up. 2. Press the left hand “Auger ON/OFF” button ON. 3. To operate in COLD mode press the “AUTO TIMER” button until it is illuminated. 4. When setting automatic times, please keep in mind it will take time for the frozen product to become liquid or vice versa. Operate in Manual Mode (without COLD Timer Activated) 1. Turn the power switch ON and wait for LED display to light up. 2. Make sure the clock button is OFF (LED light on clock button should not be lit up). 3. First turn auger ON by pressing the “Auger ON/OFF” button until it beeps. NOTE: The auger must be ON before the unit will allow the COLD or FROZEN mode to be activated. 4. Then select COLD or FROZEN mode by pressing the “PRESS TO SELECT FUNCTION” button until the light under the selection you desire is lit up. NOTE: In the COLD mode, the LED will read the actual temperature of the product (the temperature setting is preset to NSF standards and is not adjustable.) In the “FROZEN” or “OFF” mode the LED will read the current time. Setting the 12 or 24 Hour Display and oF or oC Temperature Display 1. Turn the power switch OFF. 2. Press and hold the left “AUGER ON/OFF” button and turn ON the power switch. Release the “AUGER ON/OFF” button when either “12” or “24” are shown (indicates the current hour view). 3. Press the “PRESS TO SELECT FUNCTION” button until either oF or oC is shown on the display. 4. Press the “AUTO TIMER” button until the desired temperature display type is shown (oF or oC). 5. Store the change by pressing the “PRESS TO SELECT FUNCTION” button until the current time is displayed. The unit is now ready for use. Publication Number: M620919596OPR - 10 - © 2004-2006, IMI Cornelius Inc. Ice Frost Operator’s Manual Viewing the Bowl Temperature 1. Turn ON the auger on the side that you want to display the bowl temperature (press the “AGER ON/ OFF” button). 2. Press the “PRESS TO SELECT FUNCTION” button until the “Cold” LED is lit. The display will now show the current bowl temperature in either oF or oC as applicable. CONSISTENCY ADJUSTMENT 1. To dispense the product, place the cup beneath the dispensing valve (Q) and pull the lever (R) very gently (FIGURE 10). 2. Adjusting the viscosity: To vary the viscosity of the product, turn the knob (S) as shown in FIGURE 11. Turning the knob counter-clockwise will increase viscosity (make the product denser). Turning the knob clockwise will decrease viscosity (make the product less dense). FIGURE 10 ATTENTION: This control only changes the viscosity of the product dispensed, it does not effect the COLD temperature. ATTENTION: When the level of the product inside the bowl is below the minimum level, you must switch the COLD system (OFF position), or refill the bowl, following the instructions given in the previous paragraphs. An indicator gauge for reference is located on the back of the unit approximately 6 inches below the adjustment knob. NOTE: This indicator can not be viewed on all models. FIGURE 11 © 2004-2006, IMI Cornelius Inc. - 11 -Publication Number: M620919596OPR Ice Frost Operator’s Manual QUARTERLY CLEANING AND SANITATION POST MIX SYSTEMS OPERATIONS ATTENTION: The cleaning operations must be performed with the machine disconnected from the power supply. 1. Empty the bowl of any remaining product and switch off the main switch “M”. 2. Remove the cover (B) -FIGURE 27. 3. Extract the quick couplings (C2) / (F2) - (FIGURE 12, FIGURE 13, and FIGURE 14). Pre-mix version Post-mix version FIGURE 12 FIGURE 13 FIGURE 14 4. Disconnect the probe fastenings (D2) / (E2) - (FIGURE 12 and FIGURE 13). 5. Pull the lockpin/safety pin (Y) upwards -FIGURE 15. CAUTION: There is a spring below the safety pin. Take caution when removing the pin that the spring does not fall into the unit or eject the pin. FIGURE 15 Publication Number: M620919596OPR - 12 -© 2004-2006, IMI Cornelius Inc. Ice Frost Operator’s Manual 6. Slide the locking bar (Z) -FIGURE 16 - outwards so that the bowls are fully released. Unlock relief valve on the bowl lid cap and remove (FIGURE 17). FIGURE 16 7. Unscrew the knobs (A1) so the bowls can be lowered slightly, open the tap to remove any remaining liquids and then extract it from its seating, pulling it outwards (FIGURE 17). 8. Remove the tap from its seating, pressing the two clamping wings at the same time (FIGURE 18) and pushing upwards. Bowl Lid Cap FIGURE 17 FIGURE 18 9. Remove the tap, holding the body (R) pressed downwards, then slide the lever (L) out of its seating (FIGURE 19). Wash all the parts thoroughly with hot water and mild detergent, rinse them well, and replace them. FIGURE 19 10. Separate the bowl from its cover, releasing the fastening (D1) by pulling them upwards as shown in FIGURE 20. FIGURE 20 © 2004-2006, IMI Cornelius Inc. - 13 -P...

Dieses Handbuch ist für folgende Modelle:
Standmixer - Cornelius ICE FROST (1.05 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien