Anleitung Air King, modell 9318
Hersteller: Air King Dateigröße: 132.23 kb Dateiname: c49661af-5607-4667-b659-2e8a527b4bd9.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Arrange Power Cord away from room traffic and where it will not be tripped over. 11.This Fan is not intended for use in wet or damp locations. Never locate a Fan where it may fall into a bathtub or other water container. 12. Do not use Fan outdoors. 13.This Fan is not suitable for use in hazardous locations. Please refer to National Electric Code (NEC) Article 500 or applicable state or local codes or standards relating to electrical requirements for Hazardous locations. THIS FAN DOES NOT MEET THE REQUIRMENTS OF NEC ARTICLE 500 (2002). WARNING: REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK – DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICES. SAVE THESE INSTRUCTIONS WALL/CEILING INSTALLATION 1.WOOD STRUCTURES: Locate the wall or ceiling stud nearest to the desired Fan location. Attach the Fan to the stud using a 3/8" diameter x 2" long Lag Screw (Not Supplied). (Figure 1) NOTE: ALWAYS INSTALL THE YOKE TO A MINIMUM OF 2 X 4 STUDDING. 2.STEEL STRUCTURES: Attach the Fan using a 3/8" bolt of the appropriate length, with a Flat Washer, Lock Washer and a 3/8" Nut (Not Supplied). 3.MASONARY STRUCTURES: Attach Fan using a 3/8" Lag Screw, with a Lag Shield of appropriate length (Not Supplied). (Figure 1) 4.Attach Pull Cord String and Pendant to Switch. Wall or Ceiling Stud Lag Shield (Masonary Only) Flat Washers Lag Screw Figure 1 1 5084577 Rev. B 9/07 MODEL 9318 Figure 3 Figure 2 NOTE: IN ALL CASES, IT IS RECOMMENDED THAT A FLAT WASHER BE PLACED ON BOTH SIDES OF THE FAN YOKE TO ASSIST IN SMOOTH ROTATION. Secondary Support Cable Large Guard Wires RHIGHVELOCITYAIRCIRCULATOR CAUTION: THE SECONDARY SUPPORT CABLE PROVIDED SHOULD BE USED ANYTIME THE CIRCULATOR IS MOUNTED OVERHEAD FOR ADDITIONAL SAFETY. SECONDARY SUPPORT CABLE 1.Loop one end of Cable around the Large Diameter Wires of both the Front and Rear Circulator Guard. (Figure 2) 2.Attach a Cable Clamp with the "U" on the tail side of the loop leaving a tail approximately 1 to 2 inches. Tighten Clamp Nuts. Make sure no part of the Cable interferes with the Blade. (Figure 2) 3.Wrap the other end of the Cable around a secure building joist, truss, or other support near the Fan. (Figure 3) Take up all excess slack in the Cable. CAUTION: USE ONLY THE MOUNTING HARDWARE WHICH IS RECOMMENDED FOR USE ON THIS FAN. 4.Attach the remaining Cable Clamp as indicated in Step 2. The excess tail should be trimmed to extend 1 to 2 inches past the Clamp. 5.Check the Assembly to assure the Blade is free of all obstructions. CAUTION: USE OF THE SECONDARY SUPPORT CABLE DOES NOT GUARANTEE PROTECTION AGAINST INJURY OF PERSONS, MOUNTING OF BOTH THE CIRCULATOR AND CABLE COULD FAIL IF SUBJECTED TO ABUSE, NEGLECT OR IMPROPER INSTALLATION. OPERATION 1.Plug the power cord into a properly grounded three-prong receptacle. 2.Using the Pull Cord Switch, set the desired Fan Speed. 3. WARNING: This fan should be used only in a clean, dry environment. Mounting of this product in any way other than specified in the instruction sheet will null and void the manufacturers warranty.. MAINTENANCE WARNING: ALWAYS UNPLUG CORD BEFORE SERVICING. CLEANING: Use a soft cloth and a mild soap solution such as liquid dish washing detergent. CAUTION: Do not use gasoline, benzine, thinner, harsh cleaners, etc. which will damage the Fan. Dry all parts with a soft cloth completely before reconnecting to power supply. STORAGE: When not in use, keep unit in a clean dry place. MOTOR IS PERMANENTLY LUBRICATED. LIMITED WARRANTY WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials. HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs. WHAT AIR KING WILL DO: During the warranty period, Air King will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the same or comparable model. WHAT THIS WARRANTY DOES NOT COVER: This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse, misuse or unauthorized repairs made or attempted. This warranty does not cover shipping costs for the return of products to Air King for repair or replacement. Air King will pay return shipping charges from Air King following warranty repairs or replacement ANY AND ALL WARRANTIES, EXPRESSED OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY), LAST ONE YEAR FROM THE DATE OF ORIGINAL PURCHASE OR UNTIL THE ORIGINAL PURCHASER OF THE PRODUCT SELLS OR TRANSFERS THE PRODUCT, WHICHEVER FIRST OCCURS AND IN NO EVENT SHALL AIR KING'S LIABILITY UNDER ANY EXPRESS OR IMPLIED WARRANTY INCLUDE (I) INCIDENTAL OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER, OR (II) REPLACMENT OR REPAIR OF ANY HOUSE FUSES, CIRCUIT BREAKERS OR RECEPTACLE...