Login:
Stimmen - 4, Durchschnittliche Bewertung: 3.8 ( )

Anleitung AquaPRO, modell APB150PRO

Hersteller: AquaPRO
Dateigröße: 2.36 mb
Dateiname:
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Operation Do not run pump dry. Fill pump with water before starting motor. Before removing trap cover: 1. CLOSE GATE VALVES in suction and discharge pipes 2. RELEASE ALL PRESSURE from pump and piping system If pump is being pressure tested, be sure pressure has been released before removing trap cover. Do not block pump suction. To do so with body may cause severe or fatal injury. Small children using pool must ALWAYS have close adult supervision. Fire and burn hazard. Motor runs at high temperatures, to reduce the risk of fi re, do not allow debris, or foreign matter to collect around the pump motor. Allow motor to cool prior to handling or performing maintenance. The motor is equipped with an internal thermal protection circuit to guard against overheating. The maximum ambient temperature for motor operation must not exceed rating on motor model plate. PRIMING PUMP Release all pressure from fi lter, pump, and piping system; see the fi lter owner’s manual. In a fl ooded suction system (water source higher than pump), pump will prime automatically when suction and discharge valves are opened. If pump is located above the normal pool water level remove ring and cover assembly and slowly fi ll basket and pump with water. Clean and inspect o-ring; reinstall on trap. Replace ring and cover assembly rotate clockwise to tighten cover (see Figure 3). Clamp ring must engage with pump body. Push down and rotate until internal stops are felt. Properly aligned tabs shown above in Figure 3, assure lid is securely clamped. Failure to tighten clamp ring as indicated will reduce product strength, resulting in failure of components, and bodily injury. Pump prime time will depend on vertical distance and length of suction line. If pump does not prime, make sure that all valves are open, suction pipe is submerged. Verify there are no leaks in suction lines. See Troubleshooting Guide for further assistance. Maintenance All AquaPRO® Systems pumps are shipped from the factory with DANGER and/or WARNING labels already on the pump. These labels contain a series of basic, yet extremely important safety messages for the user and bystander. Regardless of how well these labels are attached or how scratch resistant or wear-resistant they may be, it is possible that, in time, the wording may become illegible with normal use. Whenever you are repairing the pump, performing routine maintenance, or have the opportunity to inspect the pump, make sure the label is readable. If the label is not legible, replace the label with an adhesive version that is available at no charge by calling AquaPRO® Systems at 1-877-278-2797. Use only parts supplied by manufacturer. Similar looking parts may not have suffi cient strength for safe operation. The only routine maintenance needed is inspection/cleaning of strainer basket. Debris or trash that collects in basket will choke off water fl ow through the pump. Before attempting to clean basket: A. Stop pump, disconnect power at its source, lock out power, place tag on the dedicated GFCI circuit breaker indicating the power is to remain OFF, close valves in suction and discharge, and release pressure from system. Hazardous suction can trap hair or body parts, causing severe injury or death. Do not block suction. B. Remove ring and cover assembly by turning counterclockwise. If necessary, tap handles gently with a rubber mallet. C. Remove basket and clean. Inspect holes in basket for blockage. Clean basket with water and replace in basket housing. Verify basket is oriented correctly in housing. D. Clean and inspect lid o-ring; reinstall ring and cover assembly. E. Prime pump (see priming instructions). 5 APB075PRO, APB100PRO, APB150PRO, APB200PRO, APB300PRO, APB100UPRO, APB150UPRO, APB200UPRO and APB250UPRO 20 Sp Manual del usuario 0 20 40 60 80 100 0 20 40 60 80 100 120 140 160 Caudal en USGPM Carga hidrostatica dinamica total en pies de agua AquaPRO Systems Sobre carga Curvas caracteristicas 60 ciclos 1 fase 3450 RPM 10/ APB100UPRO 1 HP APB150UPRO 1.5 HP APB200UPRO 2 HP APB250UPRO 2.5 HP Caudales de la bomba para piscinas 0 20 40 60 80 100 120 0 20 40 60 80 100 120 140 160 Caudal en USGPM Carga total Curvas caracteristicas 60 ciclos 1 fase 3...

Dieses Handbuch ist für folgende Modelle:
Schwimmbecken - APB100PRO (2.36 mb)
Schwimmbecken - APB200PRO (2.36 mb)
Schwimmbecken - APB200UPRO (2.36 mb)
Schwimmbecken - APB250UPRO (2.36 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien