Anleitung Pentair, modell Small Underwater Pool Lights SunLite LTC
Hersteller: Pentair Dateigröße: 115.86 kb Dateiname: 9937093b-bab2-4874-9f81-245714d80204.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
Installation of a 12 Volt transformer is required when installing the 12 Volt model of this light. The transformer must be located: • at least 10’ from the pool wall, • installed near a grounded, 3-prong, 120V, GFCI protected outlet. If you do not have a GFCI protected outlet, have a qualified electrician install one. Do not use a 3-prong adapter. The adapter voids the grounding of the system. Do not cut the grounding pin. Do not use an extension cord! Purchase a light with a longer cord. 1. Be sure the power is off. 2. Place lamp housing on the deck above the niche. Feed the cord through the back of the lamp housing and to the conduit box. Make sure that there is enough cord to allow the fixture to be placed on the deck for re-lamping. 3. Make connections in the conduit box (be sure to follow code requirements!). Connect the supply circuit grounding wire (green, green and yellow, or bare copper) to the green ground conductor from the light fixture. Connect the line supply wire (the black or ’hot’ wire) to the black wire from the light fixture. Connect the neutral (white) supply wire to the neutral (white) wire from the light fixture. 4. Coil the remaining cord in the back of the niche and place the lamp housing in the niche. The mounting tab on the bottom of the lamp housing must be in the notch at the bottom of the niche. 5. Fasten the lamp housing into the niche with the captive leader screw at the top of the lamp housing (use a No. 2 Phillips screwdriver). Tighten this screw securely (20 inch-pounds torque) to insure good electrical bonding. NOTICE: The leader screw in the face ring may be recessed. NOTE: Do not try to loosen the strain relief (cord nut) on the back of the lamp housing; the cord is not detachable from the lamp housing. Attempting to loosen the strain relief will damage the lamp housing assembly, void the warranty and may cause an electrical shock hazard if the pool bonding is not connected and functioning correctly (see “General Safety”, Page 2). Sufficient cord to allow fixture tobe put on the deck for relampingBrass conduitPool wallFixture18” Min. Low levelprobeTo serviceTo fixtureToservice8” Min.8” Min. Fixture removedfor relamping4Ft. Min.Junction boxMax. waterlevel Figure 1: Lamp Housing Installation 5 Lamp Installation Instructions (Re-lamping) See Figure 2, Page 7, for Key numbers. 1. Be sure that the power is off. Allow the lamp to cool before relamping. 2. Remove the leader screw (Key No. 1) from the face ring and lift the lamp housing up and out of the niche. 3. Loosen the screw and nut on the clamp ring assembly (Key No. 5) until the nut is near the end of the screw. Swing the screw and nut out of the forked slot of the clamp ring assembly and bend the clamp ring open to about 4 inches. 4. To relamp 120V model, remove the lamp by turning it counterclockwise and pulling it straight out. Replace with an equivalent lamp. For the 12V model, remove the lamp by pulling it straight out while holding the spring clip back (away from the socket). Replace with an equivalent lamp. 5. Using a clean soft lint free cloth, carefully wipe all sealing surfaces on the lamp housing and lens. NOTE: Do not touch the lamp with your bare fingers. If contact occurs, clean the lamp glass with alcohol and a clean cloth. 6. To close the fixture, make sure the clamp ring is open to about 4 inches and that the nut is at the end of the leader screw. 7. Lay the face ring face down on a flat surface. Carefully align the clear lens (Key No. 4) and lens gasket (Key No. 5) over the flanged hole in the face ring (key No. 2), with the word “top” on the lens lined up with the leader screw on the face ring. The silver tape should be on top and the arrow pointing toward the lamp. 8. Align the lamp housing over the lens gasket with the word “top” inline with the leader screw in the face ring. 9. Position one half of the clamp ring around the metal flanges of the face ring and lamp housing. 10.Close the clamp ring, fitting the other half over the same flanges. 11. Swing the nut and screw into the slotted end of the clamp assembly. Tighten this screw securely (20 inch- pounds torque) to insure good electrical bonding. 12.To replace the lamp housing in the pool wall hook the bracket at the bottom of the niche and tighten the leader screw on the face ring of the lamp housing. 6 Figure 2 – SunLite® LTC Lamp Exploded View LAMP4405 0903Note gasket orientation. LAMP4405 0903Note gasket orientation. REPAIR PARTS LIST – SUNLITE® LTC LAMPS Key No. Part Description Qty. 05603 Series 12V, 75W 05605 Series 120V, 100W 05607 Series 120V, 250W 1 2 3 4 5 6 7 • • • • Leader Screw* Face Ring, SS, Assy Kit Rubber Retainer for Leader Screw* Clear Lens, Kit Gasket, Lens Clamp Ring Assembly Lamp Housing Lamp, 100W, 120V, Halogen, T-4 MC Lamp, 75W, 12V, Halogen, MR 16 Lamp, 250W, 130V, Halogen, T-4 MC Replacement Screw Kit 1 1 1 1 1 1 1 1 1 1 1 - 05601-0001 05601-0005 34620-0002 05601-0014 05601-0006 † - 79112400 - 05601-0101 - 05601-0001 05...