Anleitung Pentair, modell Light and Return Water Flow Quasar
Hersteller: Pentair Dateigröße: 273.03 kb Dateiname: b2af5c6e-2dc8-44bb-ba5d-bbc3be51b49d.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
IMPORTANT SAFETY INSTRUCTIONS......................................................... 2 SECTION II. LAMP HOUSING INSTALLATION .................................................................. 2 SECTION III. ELECTRICAL CONNECTIONS FOR STORABLE POOLS ............................ 5 SECTION IV. ELECTRICAL CONNECTIONS FOR PERMANENT POOLS ........................ 6 SECTION V. RELAMPING INSTRUCTIONS ........................................................................ 9 SECTION VI. STORAGE AND WINTERIZING INSTRUCTIONS ...................................... 10 SECTION. VII. TECHNICAL DATA. ......................................................................................... 11 A. Replacement Parts. ............................................................................................................... 11 WARNING Before installing this product, read and follow all warning notices and instructions accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for additional free copies of these instructions. Important Notice Attention Installer. This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment. Listed Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 Visit us on the Internet at: REV. F 1-6-05 1 P/N 98748000 SECTION I. IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following. 1. This light can be installed on storable above ground or permanent above ground pools. 2. A storable pool has a maximum water depth of 42 inches and is so constructed that it may be readily disassembled for storage and re-assembled to its original integrity. 3. A permanent pool has a maximum water depth over 42 inches. Do not install on therapeutic pools, hydro-massage bathtubs, spas or hot tubs. 4. To reduce the risk of electric shock, if any cord becomes damaged, return the entire transformer assembly for repair or replacement. 5. Risk of entrapment, injury or death. Use plumbing passageways only to return water to pool. Do not use as a suction device. 6. Risk of electrical shock. Connect only to a grounding type circuit protected by a ground fault circuit interrupter (GFCI). Contact a licensed electrician if you cannot verify that the receptacle or circuit is protected by a GFCI. Do not use an extension cord. 7. Locate your pool so that the wall is at least 10 feet from all electrical receptacles and at least 20 feet from all receptacles not protected by a GFCI. It is also very important to locate the pool so that it is not under any electrical wiring, that is less than 18 feet vertically above the pool wall and within an area located 10 feet outside the pool walls. The pool must also never be located under any lighting fixture or within five (5) feet measured horizontally from any fixture mounted less than five (5) feet vertically above the pool water level. 8. Risk of injury. Install the top of the lens with a minimum of 8 inches and a maximum of 10 inches below top of pool wall or in manufacturers pre-punched return fitting hole. 9. Do not use electrical equipment within 10 feet of pool wall unless specifically U.L. listed for that use. SECTION II. LAMP HOUSING INSTALLATION NOTE Installation of the lamp housing into the pool wall is the same for both the storable and the permanent above ground pools. 1. Remove the bulb retainer nut and push the bulb assembly out from the rear of the fitting body so that it will come out of the front of the fitting. The flow director will come off along with the bulb assembly; see Figure 1. Push the red cap/plug in the end of the bulb assembly. It will be removed later. 2. Unscrew the threaded wall flange from the fitting body by rotating it counter-clockwise. P/N 98748000 2 REV. F 1-6-05 NOTE Retain the gaskets supplied and keep them accessible. 3. Use the Teflon™ tape provided. Snugly wrap the threaded wall flange in a clockwise direction (as viewed from the back) starting at the edge of the threads; see Figure 2. Work towards the flange lip (overlapping 1/2 of the tape width with each wrap) then back towards the starting point. • If you have a new pool, move on to step 10. • If the water level is below the return fitting on an existing pool, remove the old fitting and move on to step 10. • If the pool is full of water, follow steps 5 through 9. NOTE Steps 4 through 8 require two (2) No. 9 winterizing plugs (not supplied). 4. Remove the existing eyeball fitting from the return fitting on your pool wall, see Figure 3. 5. Place a winterizing plug in the front side of the existing return fitting and disconnect the return hose and clamp from the existing fi...