|
Dieses Gerät hat auch andere Anweisungen:
Anleitung Zusammenfassung
@1 B.R.F. FREQUENCY control Sets the rejection frequency when the "BRF" switch is set to "-6dB"/"-12dB". (page 8) .............................................................................................................................. .................................................................................................................................................................................................................................................................................................................................................................................. Amplifier Control System Indicator MENU 2 / 3 Display mode You can set up the display items as follows: 1 Enter Menu mode Press the [MENU] button. "VOLT"/"CURR"/"TEMP"/"FAN" is displayed. 2 Select a display item Press the [2] or [3] button. The display items are switched in the following sequence. Display Information "VOLT" Indicates the source voltage (V). "CURR" Indicates the current consumption (A). "TEMP" Indicates the internal temperature (°F/°C). "FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF". 3 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is displayed. Separate Amp Control You can control sounds using the Amplifier Control function of the unit. 1 Enter Menu mode Press the [MENU] button. 2 Select the Menu item Press the [MENU] button. The setup items are displayed approximately 1 second first, then the set values are displayed. 3 Adjust the Menu item Press the [2] or [3] button. The setup items and set values are switched as follows. Display Range Adjustment Item "VOLT"/"CURR"/"TEMP"/"FAN" For the operation method refer to 'Display mode' "BASS" 60/80/100/200 (Hz) Bass Center Frequency "BA G" B–15 — B+15 (dB) Bass level "BA Q" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor " EXT" ON/OFF When the bass extend is set to ON, low frequency response is extended by 20%. "VOL" –20 — 0 (dB) Volume offset "TEMP" FAHR (Fahrenheit) or CELS (Centigrade) The Fahrenheit or Centigrade temperature unit can be selected for the Display mode. "DEFA" For the operation method refer to 'Default' "AMP" 0 — 7 The ID Number you have assigned is displayed. 4 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed. Default Resets all values you have set to the initial (default) values. 1 Enter Menu mode Press the [MENU] button. 2 Select Default mode Press the [MENU] button. Select the "DEFA" display. 3 Resets the value to its default Press the [3] button for at le...
Dieses Handbuch ist für folgende Modelle:Auto Verstärker - KAC-PS811D (526.5 kb)