|
Anleitung Zusammenfassung
26210086 Input frequency range MHz 90-862 Input level range dB.V 48-78 Output frequency range MHz 5-65 Max. output level dB.V 113-118 Power consumption W 3.5 Transmission protocol DOCSIS/EuroDOCSIS 2.0 Suitable for VGO 939, VGO 939-1G, VGF 939, VGF 939-1G, VOS 952/953, VOS 952-1G, VOS 953-1G, ORA 9022, ORA 9022-1G, ORA 920/921, VGP 9033 as of version A03 (Nov. 2008), VGP 9033-1G, VGP 9041 as of version A02 (Nov. 2008), VGF 9030/9040 16 HTE 10 - Hand-held unit With the HTE 10 hand-held unit one is able to adjust correspondingly equipped devices on site. Using the 'Up' and 'Down', 'Menu' and 'Enter' buttons, one is able to change and set the values on the 4-line display. The display is illuminated and easy to read. The hand-held unit presents the following functions: • All appropriately equipped devices or modules can be adjusted and operated • All settings are displayed • The last settings are saved (copy function) • The hand-held unit is power-supplied by the respective module • Distances: Data transfer between HTE 10 and the device or module over max. 14 m Standard connection cable: 2 m (included in delivery scope) Can be extended to 14 m (TDK 10) • 4-line display, illuminated • Language: English • Splash-proof/shock-proof • Ambient conditions: - Ambient temperature: -20 to +50 °C - Suitable for outdoor application - Protection category: IP 54 • Control signal: Serial, RS 232 • Connection: Sub D, 9-pin • Accessories (not included in delivery scope): TDK 10 (Order no. 26210054): Connection cable 14 m TDK 12 (Order no. 26210076): PC connection cable for HTE 10 (for software updates) 17 Accessories EAC 90-1G, 93-1G, 94-1G – Tap-off cards EBC 00-1G and EBC 01E-1G – Null cards (output, input) • Plug-in modules to extend the corresponding devices to two outputs • When inserted in the amplifier's input section these modules can be used to configure a loop-through input • Plug-in modules for operation of the VGP 90xx distribution network amplifiers with one input or output • EBC 01E-1G: For operation on the input insert position • EBC 00-1G: For operation on the output insert position EBC 90-1G – Splitter, 2-way Type EBC 01E-1G EBC 00-1G Order no. 24510121 24510119 Frequency range MHz 5-1000 5-1000 Through loss .) dB < 0.5 < 0.5 1) The through loss is the signal loss between the unit's output and output 1 when the insert is inserted in the output section insertion point or between the unit‘s input and the tap output when the insert is inserted in the unit's input section (input configuration section) Type EAC 90-1G EAC 93-1G EAC 94-1G EBC 90-1G Order no. 24510116 24510115 24510114 24510113 Frequency range MHz 5-1000 5-1000 5-1000 5-1000 Through loss .) 5-610 MHz dB < 1.3 < 2.1 < 0.5 < 3.6 Through loss .) 610-862 MHz dB < 1.3 < 2.3 < 0.6 < 3.8 Through loss .) 862-1000 MHz < 1.5 < 2.6 < 0.9 < 3.9 Tap loss dB 10 6 20 Like through loss Decoupling 5-65 MHz dB > 28 > 23 > 38 > 28 Decoupling as of 65-610 MHz dB > 26 > 23 > 33 > 22 Decoupling as of 610-862 MHz > 24 > 23 > 30 > 20 Decoupling as of 862-1000 MHz > 22 > 20 > 28 > 18 ERC 22 - C-line pre-emphasis equaliser • Generates pre-emphasis based on the C-line specifications of Kabel Deutschland • For use in the amplifiers VGP 9041/VGF 9040 • Application in the universal input insert position ("Forward 1") Type ERC 22 Order no. 24510085 Transmission range MHz 50-862 Nominal impedance . 75 Pre-emphasis For C-lines Basic loss (at 862 MHz) dB 1 Return loss dB 23 -1/oct. 1) The through loss is the signal loss between the unit's output and output 1 when the insert is inserted in the output section insertion point or between the unit's input and the tap output when the insert is inserted in the unit's input configuration section 18 Accessories ERS 800 – System equaliser ERZ 940 – De-emphasis equaliser • System equaliser for use in special applications • Characteristics: Cable-equivalent pre-emphasis in the range 47-700 MHz: 3 dB (at 47-862 MHz: 4 dB) Cable-equivalent pre-emphasis in the range 700-862 MHz: 3 dB (equivalent to additional emphasis in the range 700-862 MHz by 2 dB) • Cable-analogue 7 dB Type ERZ 940 Order no. 24510059 Transmission range MHz 47-862 Nominal impedance . 75 De-emphasis dB 7 ± 1 Basic loss (at 47 MHz) dB 0.3 Return loss dB 20-3 Principal frequency response curve ERS 800012345670100200300400500600700800MHzdB86247 ERZ 630 – Equaliser Type ERS 800 Order no. 24510109 Transmission range MHz 47-862 Nominal impedance . 75 Cable-equivalent pre-emphasis, 47-700/(equivalent to 47-862) MHz: dB 3/(4) Cable-equivalent pre-emphasis in the range 700-862 MHz dB 3 Basic loss (at 862 MHz) dB 0.5 Return loss dB > 15 • Equaliser 47-630 MHz • Switchable in 2-dB steps from 2-18 dB (cable equivalent) Type ERZ 630 Order no. 24510108 Transmission range MHz 47-630 Nominal impedance . 75 Basic loss (at 47/630) dB 0.5/1.5 Equalisation, adjustable in 2-dB steps dB 2-18 19 Accessories De-emphasis equalisers/attenuators Remote-feed fuse FUN 15 25010017 ERD 810 24510110 ERD 813 24510...
Dieses Handbuch ist für folgende Modelle:Auto Verstärker - VGF 9030/9040 (6.76 mb)
Auto Verstärker - VGO 939-1G/VGF 939-1G (6.76 mb)
Auto Verstärker - VGP 9033-1G/9041 (6.76 mb)