Anleitung Zusammenfassung


This hard shutdown condition can only be reset by shorting the FIREBOX or UL connectors on the left side of the circuit board to ground. If a firebox is used in the installation, The firebox door should be opened and closed to reset the circuit board. Once the operator is installed or if the control board is replaced, you will need to program the control board for proper current sensing. The operator should be functional and the open and close limits set. 1. Push and hold the LED ENABLE button for five seconds. The “STOP” LED will blink indicating the board is in learn mode. 2. Cycle the gate three full times (must reach the open and close limit switches on each cycle). The “STOP” LED will now stay illuminated. 3. Adjust the current sensitivity pot to insure safe operation COUNTER CLOCKWISE CLOCKWISE More sensitivity Less sensitivity Gate is easy to current Gate is harder to sense current sense The current sensitivity may be readjusted at any time without relearning the board. Periodically check the current sensitivity for safe operation. 12 835/836 Control Board Parts Identification LED Enable & Learn Mode Push Button Optional Device Inputs Stop Circuit Jumper Fire & ETL Inputs Emergency Bypass Reverse Battery Polarity Indicators Optional Device Input Remote Monitor Outputs GateLink Connector Microprocessor Timer To Close - Dual Gate Delay - Current Sensitivity - AdjustmentsProgram Switches Actuator Connector (Master) Actuator Connector (Slave) Control Board Reset Hard Shutdown Reset Operate Push Button 13 Actuator Connector 1 3 5 7 2 4 6 8 Board Actuator Function Cable Pin 1 Orange Open Limit Pin 2 White Close Limit Pin 3 Black Motor (positive on open, negative on close) Pin 4 Red Motor (negative on open, positive on close) Pin 5 Green Common for both limit switches Pin 6 Yellow Feedback from intelligent actuator (816E/816EX) Pin 7 Black Battery Negative Pin 8 Red Battery Positive EMERGENCY BYPASS (open only) Applies battery voltage directly to motor to open gate if control board fails. User must unplug before gate opens to maximum travel or 15 amp fuse will open. Fuse should be checked before returning gate to service. Remote Outputs 12V Supplied battery voltage SLV Slave Operator Indicator (indicates slave side of gate is closed) +12V when on closed limit. Ground when off of closed limit. MAS Master Operator Indicator (indicates master side of gate is closed) +12V when on closed limit. Ground when off of closed limit. GND Battery supplied ground SIREN Connect to siren + applies +12V when gate(s) are running, or in hard shutdown GND Battery supplied ground LOCK Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable) GateLink Connector Connects control board to a computer using GateLink software. This software can monitor and diagnose the functions of the microprocessor. Ask your sales- person about this feature. 14 Adjustments TIMER TO CLOSE Adjusts time before gate automatically closes Adjustable 5 to 70 seconds. DUAL GATE DELAY Adjusts delay between master and slave operation 0-4 seconds (836 only for use with magnetic, solenoid, and other locking de vices) CURRENT SENSITIVITY Increases or decreases the Auto Reverse sensitivity. Push Buttons OPERATE When depressed, activates the gate. Used for initial installation and testing. Hard Shutdown Reset Resets the operator when the gate current senses twice before fully opening or closing. LED ENABLE When depressed, activates LEDs for 15 minutes to assist in installation and troubleshooting. Hold the push button down for five seconds to put the board in program mode. RESET Resets the microprocessor. Returns processor to last known state. Jumpers STOP CIRCUIT JUMPER When the STOP CIRCUIT program switch #5 must be ON JUMPER is connected, the gate will operate normally. STOP CIRCUIT JUMPER When a 3-button station is con- program switch #5 must be OFFnected to the board, the STOP CIRCUIT JUMPER must be removed. 15 Program Switches OFF ON 1 TIMER TO CLOSE Gate does not automatically close. Gate automatically closes. 2 TIMER TO CLOSE OPT. Gate automatically closes from Gate automatically closes only when completely any position after opening. open (open limit engaged). 3 SLAVE DISABLE Enables slave side (dual gate use). Disables slave side. (single gate use) 4 SIREN DELAY Siren (optional) active when gate is Siren (optional) starts 5 seconds before gate moves. moving. 5 ‘STOP’ CIRCUIT ENABLE Must hold down open or close Normal operation buttons to move gate. Gate stops Momentary open or close input runs gate to limit. when button released. 6 LOCK TYPE For 12V mechanical (solenoid) locks. For 12V magnetic locks. (+12V for 4 seconds on open cycle) (+12V when on close limit) 7 COAST ENABLE Gate will stop immediately when at Gate will coast (minimally) when it reaches limits. Open or Close limit Recommended for 7500 slide operator only. 8 FREE EXIT OPT. A free exit input will open gate from A free exit input will open gate from any close...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - 1550ETL (1.03 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien