Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung DKS Enterprises, modell 6100

Hersteller: DKS Enterprises
Dateigröße: 5.9 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Auto-close timer (when turned on) SW 1, switch 4. Adjust from 1 second (full counter clockwise) to approximately 23 seconds (full clockwise). Dry relay contacts (terminals 16-17) can be set for Normally Open (NO) or Normally Closed (NC) operation by placing the relay shorting bar on the N.O. or N.C. pins respectively. 1 ON 2 3 4 5 6 7 8 SW 1 Loop Detector Loop Detector 1 23 9410 EXIT REVERSE SHADOW SHADOW OUTPUT 9409 Dry Relay Auto-Close Timer Contact 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 NC NO 1 ON 1 2 3 4 5 6 7 8 ON 2 3 4 5 6 7 8 NC NO Set the DIP-switches on the circuit board to the desired setting. See switch-setting charts on next 2 pages. 1 ON 2 3 4 5 6 7 8 1 ON 2 3 4 5 6 7 8 SW 1 SW 1 SW 2 SW 2 DIP-Switches Tracker LEDs Power LED Input LEDs Pulse 1 LED Primary Operator Pulse 2 LED Secondary Operator Loop LED Board Ground Board Power Loop LED 4502 3.2 DIP-Switch SW 1 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator. SW 1 (Top 8 Switches) Switch Function Setting Description 1 and 2 Relay 1-OFF 2-OFF Relay activates when gate is open. 1-OFF 2-ON Relay activates when gate is not closed. 1-ON 2-OFF Relay activates when gate is opening and open. 1-ON 2-ON Relay activates when gate is opening and closing. 3 Open loop OFF Terminal 12 is the output from the open detector. Logic Output ON Terminal 12 is an open input. 4 Auto-Close Timer OFF Auto-close timer is OFF. Manual input required to close gate. ON Auto-close timer is ON. Adjustable from 1-23 seconds to close gate. 5 Slide Gate OFF OFF for Slide gate operator. Swing Gate ON ON for Swing gate operator. 6 3-Button OFF OFF when using a 3-button station. Single Button ON ON when using a single button control. 7 Dual Operators OFF Switch must be OFF when bi-parting (dual) gates are used. Single Operator ON Switch must be ON for single operator. 8 Tamper Protect OFF Tamper protect is OFF. ON Tamper protect is ON. Switches 1-2 These work in conjunction with each other and determine when the relay on the board will be activated. This relay can be used as a switch for various functions such as illuminating a warning light when the gate is moving, or turning on a green light when the gate is full open. This relay is NOT available for these uses if it is being used for the shadow loop function. Switch 3 Determines if the output of the loop detector (DoorKing loop detectors only) plugged into the EXIT port will be sent directly to the microprocessor to open the gate, or if the output is directed to Terminal 4 where it can then be connected to other input terminals. Switch 4 Turns the auto close timer on or off. Maximum time that the close timer can be set for is approximately 23 seconds. Switch 5 This switch enables the 4502 circuit board to be used in either a swing gate or slide gate application. Some older DoorKing slide gate operators did use the 4501 circuit board for control. This switch is here to allow use of this board on these older products. Switch 6 Sets up the circuit board for single button or 3-button (open-close-stop) logic (DoorKing 3-button control stations only). Keep this switch in the ON position for single button control. Switch 7 Sets up the circuit board for single or primary / secondary (dual) gate operation. Switch 8 If the gate is forced open, the tamper-protect system will start the motor in the close direction when the operator senses the forced open condition. 6050-065-L-11-08 23 3.3 DIP-Switch SW 2 Settings OFF ON Reverse Loop Shadow Loop Terminal 15 is a normal Reverse input. Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle. Switch Function Setting Description SW 2 (Bottom 8 Switches) Secondary Operator Opening Direction OFF ON OFF ON OFF ON Seft-Test Motor Control Primary Operator Opening Direction 2 3 4 6 1 Normal operation. Self-test mode. Operator MUST be disconnected from gate to run self test. Switch is OFF when both primary and secondary operator motors are powered from main terminals 4 and 5. Applies to operators originally manufactured with 4501, Rev O boards or lower). Switch is ON when secondary operator motor is powered from the secondary motor terminals. Applies to operators manufactured with 4501, Rev P boards and higher, and all 4502 boards. 5 7 8 Gate Overlap Not Used Not Used OFF ON OFF OFF Primary and secondary operators start at the same time. Secondary operator starts 1-2 seconds prior to the primary operator. Leave in the OFF position. Leave in the OFF position. OFF ON Opening direction of arm using OFF setting. Gate opens counter-clockwise. Opening direction of arm using ON setting. Gate opens clockwise. Opening direction of arm using OFF setting...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - 6050 (5.9 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien