Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Chamberlain, modell 1150

Hersteller: Chamberlain
Dateigröße: 2.37 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Two representative installations are shown. Yours may be different. Hanging brackets should be angled (Figure 1) to provide rigid support. On finished ceilings, (Figure 2) attach a sturdy metal bracket (not supplied) to a structural support before installing the opener. 1. On each side of opener measure the distance from the opener to the structural support (or ceiling). 2. Cut both pieces of the hanging bracket to required lengths. Flatten one end of each bracket and bend or twist to fit the fastening angles. Do not bend at the bracket holes. Drill 4.5mm (3/16") pilot holes in the structural supports (or ceiling). Attach flattened ends of brackets to supports with wood screws. 3. Lift opener and fasten to hanging brackets with screw, lock washer and nut. Check to make sure rail is centered over the door. 4. Remove 25mm (1") board. Operate door manually. If door hits the rail, raise header bracket. 5. Use rail grease and lubricate inside surface of rail. Figure 1 Figure 2 SHOWN ACTUAL SIZE 114A2845 16 INSTALLATION STEP 6 Install the door control Locate the door control within sight of the door at a minimum height of 1.5m where small children cannot reach, and away from all moving parts of the door and door hardware. 1. Strip 6mm of insulation from one end of the bell wire. Connect it to the two screw terminals on the back of the door control by color: white wire to 2 and white/red wire to 1. 2. Fasten the Lighted Door Control Button securely with 6ABx1-1/2” screws. If installing into drywall, drill 4mm holes and use the anchors provided. 3. Run the bell wire up the wall and across the ceiling to the opener. Use insulated staples to secure the wire in several places. Do not pierce wire with a staple, creating a short or open circuit. 4. Receiver terminals are located on the back panel of the opener. 5. Strip 11mm of insulation from the end of the bell wire and insert in wire trap: white to 2 and white/red to 1. 6. Permanently attach the entrapment warning label to the wall near the door control, and the manual release/safety reverse test in a prominent location on the inside of the garage door. Bell WireThe 92WHT-2RED-1Lighted DoorControl ButtonTerminal ScrewsLighted DoorControl ButtonBell WireScrew 6ABx1-1/2” Lighted Door Control ButtonDrywall AnchorsInsulated StaplesHARDWARE SHOWN ACTUAL SIZE Remote Control Wall Mount (optional) 1. Locate wall mount bracket at least 1.5m above the floor. 2. Attach to the wall with 2 x o 3.5 max flat head screws (not provided). 3. Slide remote control onto wall mount bracket. NOTE: Tightening the wall mount screws will reduce clearance between bracket and wall. 114A2845 17 To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is not connected BEFORE installing door control. To prevent possible SERIOUS INJURY or DEATH from a closing garage door: • Install door control within sight of garage door, out of reach of children at a minimum height of 1.5m, and away from all moving parts of door. • NEVER permit children to operate or play with door control push buttons or remote control transmitters. • Activate door ONLY when it can be seen clearly, is properly adjusted, and there are no obstructions to door travel. • ALWAYS keep garage door in sight until completely closed. NEVER permit anyone to cross path of closing garage door. WIRING INSTRUCTIONS FOR ACCESSORIES • Place entrapment warning label on the inside of door as a reminder of safe operating procedures. Place the manual release/safety reverse test label in plain view on the inside of the garage door. KEY SWITCH MODEL 059009 To opener terminal: white to 2; white/red to 1. SAFETY INFRARED REVERSING SENSOR MODEL 062153 To opener terminal screws: white to 2; Black to 3. DOOR CONTROL PANEL 062159 To opener terminal: white to 2; white/red to 1. INSTALLATION STEP 7 Install the Light • Press the release tabs on both sides of lens. Gently rotate lens back and downward until the lens hinge is in the fully open position. Do not remove the lens. Install a 40 watt maximum (socket size E27), light globe in the socket as shown. • The light will turn on and remain lit for 2-1/2 minutes when power is connected. After 2-1/2 minutes it will turn off. • Reverse the procedure to close the lens. Replace burned out globes with rough service light globes. Release tabs of lens40W MaxLight GlobeSocket 114A2845 18 INSTALLATION STEP 8 Attach the Emergency Release WWARNARNINGINGCAUTIONCAUTIONWARNINGWARNING • To prevent possible SERIOUS INJURY or DEATH from Rope and Handle a falling garage door: • Thread one end of the rope through the hole in the top of the red handle so "NOTICE" reads right side up as shown. Secure with an overhand knot at least 25mm from the end of the rope to prevent slipping. • Thread the other end of the rope through the hole in the release arm of the outer trolley. • Adjust rope length so the handle is 1.8m above the floor. Secure with an overhand knot. If it is necessary to cut the rope, heat seal the...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - 1140 (2.37 mb)
Safety Gate - 1145 (2.37 mb)
Safety Gate - 1145jg (2.37 mb)
Safety Gate - 1146 (2.37 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien