|
Anleitung Zusammenfassung
WIRING INSTRUCTIONS FOR ACCESSORIES Infrared Reversing System: Wall ConTrol To white & black opener terminals Pushbuilon Key Switch: To red & white opener terminals 13 Installation STEP 7 Install Lights and Lenses Make sure antenna wire is bent down before installing lights and lenses. 75 WattMax. Install a 75 Watt maximum light bulb in each socket as shown. The lights will turn on and remain lit for 4-1/2 minutes when power i-sconnected. After 4-1/2 minutes they will turn off. For constant light, press the Light push button on the Wall Control. LightLensBUlb_ Guide If light bulbs burn out prematurely due to vibration, f// replace with bulbs specifically packaged for "Garage Door Openers". INSTALLING LENS: Lens Tab NOTE: Force and limit adjustment settings are located on opener side panels. For convenience, lenses may be installed after Adjustment Step 3, Page 18. Slide each lens into the guides tabs into lens slots. as shown. Snap bottom STEP 8 Connect Electric Power TO AVOID SERIOUS PERSONAL INJURY FROM ENTANGLEMENT, REMOVE ALL ROPES CONNECTED TO THE GARAGE DOOR BEFORE OPERATING OPENER. TO AVOID DAMAGE TO GARAGE DOOR AND OPENER, MAKE DOOR LOCKS INOPERATIVE BEFORE CONNECTING ELECTRIC POWER. USE A WOOD SCREW OR NAIL TO HOLD THE LOCKS IN "OPEN" (UNLOCKED) POSITION. INSTALLATION & WIRING MUST BE IN COMPLIANCE WITH LOCAL ELECTRICAL AND BUILDING CODES. OPERATION AT OTHER THAN 120V 60Hz WILL CAUSE OPENER MALFUNCTION AND DAMAGE. Opener MUST be permanently wired or plugged into a grounded 3-prong receptacle wired according to local electrical codes. DO NOT use a 2.wire adapter. DO NOT use an extension cord. PERMANENT WIRING CONNECTION (If required by local code.) GroundTab S_v Green Wire RIGHT WRONG IF LOCAL CODES REQUIRE PERMANENT WIRING: DISCONNECT POWER AT THE FUSE BOX BEFORE PROCEEDING. White Wire PROCEDURE: Refer to illustration. Make connection through the 7/8" diameter hole in top of opener chassis. 1. Remove opener chassis cover by removing the cover screws. 2. Remove attached 3-prong cord. CAUTION: BE SURE THE UNIT IS GROUNDED ACCORDING TO LOCAL CODE. 3. Connect the black (line) wire to black wire on terminal block; white (neutral) wire to the white terminal wire; IMPORTANT NOTE: TO AVOID INSTALLATION the green (ground) wire to green ground screw. DIFFICULTIES, DO NOT RUN OPENER NOW. 14 Installation STEP 9 Install Door Bracket and Plate Follow instructions which apply to your door type as Illustrated below. ALWAYS RE NFORCE THE NSIDE OF DOOR--BOTH VERTICALLY AND HOR ZONTALLY--W TH 2x4 TO PREVENT DAMAGE TO LIGHTWEIGHT AND METAL GARAGE DOORS OR ONES WITH GLASS PANELS BOARDS OR ANGLE IRON. The horizontal brace should be st least 6 feet long. The vertical brace should cover height of top panel. Check with your garage door manufacturer for a door re=nforcement kit for an opener installs[ion. Sectional Door Installation Procedure 1. Assemble door bracket and plate as shown. Center bracket on previously marked vertical guideline. 2. Position the bracket assembly on the face of the door Header B_acket within the following limits: A) The top edge of the bracket 2"-4" below the top edge of the door. B) Directly below any structural support across the top VeStal SECTIONAL DOOR Center of the door. Line Placement depends on your particular needs. 3, Mark and drill 5/16" TOP and BOTTOM fastening holes, Secure bracket as shown. DoorBradder& plate Assy, Top of Door DoorBrad_t Ptate Nut Reinfomernent Boardfar Lightw_ht Doors ReinforcementBoard Washer 5/16" One-Piece Door Installation Procedure NOTE: Door bracket has left and right side fastening NOTE: The door bracket may be installed on face of holes. Assemble and install the door bracket and plate door if required for your installation. (Refer to dotted if your installation requires top and bottom fastening line drawing.) HOWEVER, drill 3/16" pilot holes and holes. substitute 5/16"x 1-1/2" lag screws (not supplied) to fasten the bracket to the door. 1, Center bracket (with or without plate as required) on top edge of door as shown. Mark holes. 2. Drill two 5/16" holes and fasten the door bracket with ONEPIECEDOOR hardware supplied. NOTE: If the door has no exposed framing, drill 3/16" pilot holes and use 5/16" x 1-1/2" lag screws (not supplied) to fasten bracket to top of door. Door --HeaderWall - Bracket Optional DoorBracket Face of Door Inst.'zllation Plate (Optional) Vertical Cenler-- Une 15 Installation STEP 10 Connect Door Arm to Trolley Follow only those instructions which apply to your door type. SECTIONAL DOOR INSTALLATION Make sure garage door is closed tight. Pull the emergency release handle to disconnect the trolley. Manually move outer trolley back to the center of inner trolley as shown in Figures A, B and C. FIGA:Fastenstraightdoorarmsection FIGB:Bringarmsectionstogether,Find FIGC:Ifholesincurvedarm are ABOVE to outer trolley with a clevis pin. Secure two pairs of holes that line up and join holes in straightarm, disconnect straight the connection with'a ...
Dieses Handbuch ist für folgende Modelle:Safety Gate - 139.53515SR - I/2HP (1 mb)