Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Linear, modell J-S

Hersteller: Linear
Dateigröße: 3.16 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


FOLLOW ALL LOCAL ELECTRICAL CODES OR THE NATIONAL ELECTRICAL CODE. WARNING FAILURE TO TEST REVERSING SYSTEM COULD RESULT IN DEATH OR SERIOUS INJURY. TEST THIS SYSTEM ONCE A MONTH. ! WARNING IMPORTANT SAFETY INSTRUCTIONS FOR OWNER . Understand all of the operating features of your door control system at the time of its installation. Your installing dealer will demonstrate them for you. . NEVER let children operate or play with door controls. Keep the Remote Control (where provided) away from children. . Personnel should keep away from a door in motion and keep the moving door in sight until the door is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. . TEST THE DOOR OPENER’S SAFETY FEATURES AT LEAST ONCE A MONTH. After adjusting either the force setting or the limit of travel, ALWAYS RETEST the Operator’s safety features. Failure to ADJUST THE OPERATOR PROPERLY may cause SEVERE INJURY OR DEATH. . DO NOT over adjust the force setting to compensate for a poorly working door. . To prevent the motor protector from tripping - Do not exceed 10 door cycles per hour. . IMPORTANT: The hardware box contains a caution label which states: “This door is operated by a light duty operator. To prevent the motor protector from tripping - Do not exceed 10 door cycles per hour.” Permanently install this label adjacent to the door, near the push button station, at the eye height of the average adult, approximately six feet above the floor). Do not paint over this label. . If possible, USE THE MANUAL RELEASE only when the door is closed. Use caution when using this release when the door is open. WEAK OR BROKEN SPRINGS MAY ALLOW THE DOOR TO CLOSE RAPIDLY, CAUSING SEVERE INJURY OR DEATH. . KEEP THE GARAGE DOOR PROPERLY BALANCED. See the door manufacturer’s owner's manual. An improperly balanced door COULD CAUSE SEVERE INJURY OR DEATH. Have a TRAINED DOOR SYSTEMS TECHNICIAN MAKE REPAIRS TO CABLES, SPRING ASSEMBLIES AND OTHER HARDWARE. . Inspect and maintain your door system as described in this manual. . SAVE THESE INSTRUCTIONS TO REDUCE THE RISK OF SEVERE INJURY OR DEATH: WARNING ! READ AND FOLLOW ALL INSTRUCTIONS! OPERATION & ADJUSTMENT INSTRUCTIONS 15 Changing the Switch Selectable Operation Modes The following modes are selected by setting the on-board dip switches, Figure 14 at right shows where the switches are located on the operator control board. For each Operational Mode, the switches are set to either ON or OFF according to the table at right below. For all the modes, if an approved entrapment protection (EP) reversing device as described on page 3 of this manual is attached to the input labeled “Photo”, it will function as noted. Once an approved EP device is recognized by the control board it is monitored for correct operation. If the device becomes inactive then the mode will default to constant pressure activation for close regardless of the dip switch setting. In order for any of the Momentary Contact to Close operation modes (B2, TS, T) to become active an approved Entrapment Protection (EP) Reversing device (see Page 3) must be properly installed and connected to the operator. The switches must be set to one of the six Operational Mode combinations for the operator to function. It order for the NO (Normally Open) Reverse or NC (Normally Close) Reverse inputs to function, you must first install an operational approved Entrapment Protection (EP) Reversing Device. C2 Operation (Factory default) Open Button: Momentary activation; open override of closing door. Close Button: Constant activation, door will stop when button is released. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A. B2 Operation Open Button: Momentary activation; open override of closing door. Close Button: Momentary activation. Stop Button: Momentary activation; stops open, close or reverse action. Single Button: Momentary activation to open; open override of closing door, closes door from mid-stop or open limit. EP Reverse (Photo Input): Momentary activation will reverse a closing door, reverse to full open (ignores mid-stop) unless stopped by stop pushbutton input. Mid-Stop: Activation stops an opening door; momentary contact of open button at mid stop will restart door to full open position; if door is moving open, constant pressure on open button will bypass mid-stop. Auto Close Timer: N/A. D1 Operation Open Button: Constant activation; open override of closing door. Close Button: Constant activation, door will stop when button is released. S...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - H-S (3.16 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien