Anleitung Linear, modell SWR

Hersteller: Linear
Dateigröße: 1.02 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A wireless contact sensor shallfunction under the intended end-use conditions. RECEIVER INSIDE GATE OPERATORGATE EDGE TRANSMITTERSEPARATE PEDESTRIAN GATE REQUIRED7FT. MINIMUM DISTANCE AWAY FROM GATE EDGE MOUNTED ONLEADING OUTSIDE EDGE OF GATE WIRE EDGESSHOWN TO THE CLOSE OBSTRUCTION INPUT ONLY WARNING One or more contact sensors shall be located on theinside and outside leading edge of a swing gate.Additionally, if the bottom edge of a swing gate is greater than six inches (152 mm) above the groundat any point in its arc of travel, one or more contactsensors shall be located on the bottom edge.A hardwired contact sensor shall be located and itswiring arranged so that the communication betweenthe sensor and the gate operator is not subjected tomechanical damage.A wireless contact sensor such as one that transmitsradio frequency (RF) signals to the gate operator forentrapment protection functions shall be located wherethe transmission of the signals are not obstructed orimpeded by building structures, natural landscapingor similar obstruction. A wireless contact sensor shallfunction under the intended end-use conditions. EDGES MOUNTED ACROSSBOTTOM OF GATE ITEM DESCRIPTION 1 GATE ( REFERENCE ONLY) 2 EDGE 3 EDGE EXTRUSION 4 SPACERS ( 3) 5 8-32 X 1" SCREWS ( 3) 6RETAININGBRACKET 5 1 2 34 6 Safety Edge Layout Illustration REVERSING EDGE ASSEMBLY CLOSE-UP Photoeye Installation Illustration SEPARATE PEDESTRIAN GATE REQUIRED 7 FT. MINIMUM DISTANCE AWAY FROM GATE OBSTRUCTION DETECTING APPLICATION (WIRE TO CLOSE OBSTRUCTION) OBSTRUCTION DETECTING APPLICATION (WIRE TO OPEN OBSTRUCTION) PHOTOEYE REVERSE APPLICATION(WIRE TO REVERSE) BEAM PATH BEAM PATH BEAM PATH THIS DRAWING IS INTENDED TO DRAW ATTENTIONTO POSSIBLE LOCATIONS FOR THE INSTALLATION OF CONTACT OR NON-CONTACT OBSTRUCTION SENSING DEVICES. OTHER AREAS OF ENTRAPMENT MAY EXIST DEPENDING ON EACH SPECIFIC INSTALLATION. CARE MUST BE TAKEN TO POSITION PHOTOEYESSO THAT NUISANCE TRIPPING IS MINIMIZED. REFER TO CONNECTION ILLUSTRATIONS FOR DETAILS SWR • SWC • SWD Swing Gate Operator Installation Guide - 20 -227965 Revision X13 3-28-2008 Dual Gate Installations Two operators can be used in dual gate installations. The operators communicate with each other through the 3-wire COMM LINK terminals. When one operator activates, the COMM LINK connection signals the other operator to activate. Each operator functions independently, controlling its gate and monitoring its inputs and accessories. A three-wire shielded conductor cable is required to connect two operators together for dual operation. Use Belden 8760 Twisted Pair Shielded Cable (or equivalent) only – P/N 2500-1982, per foot). . NOTE: The shield wire should be connected COMM LINK terminal “C” in both operators. Three of the programming functions available are only used for dual gate installations: • Dual Gate Enable Dual Gate Enable must be set for all dual gate installations. • Stagger Mode The Stagger Mode function determines if the operator has a delayed open or a delayed close. In dual swing gate installations, typically one operator is programmed for delayed open, and the other operator is programmed for delayed close. • Stagger Delay Time The Stagger Time sets the length of the delay for the Stagger Mode. See Pages 12 & 14 for details on these three dual gate programming functions. Gate Operation Open Button Opens the gate. If the Controller is programmed to stop opening the gate at mid-travel, a constant press of the OPEN button will override the Mid-travel Stop and completely open the gate. If the Auto Close Timer is set, it will be suspended until the OPEN button is released. Close Button Closes the gate if the gate is open. Also closes the gate if the gate is in the process of opening. Stop Button Stops the gate from opening or closing at any time. Single Input Opens the gate if it’s closed and closes the gate if it’s open (open-close programming option). Activating the input while the gate is moving will reverse the gate. Can be programmed to stop the gate while the gate is moving (open-stop-close programming option). Fire Department Input Fully opens the gate when the input is activated. Overrides the Mid-travel Stop and Auto Close Timer (if either is programmed for the gate). The gate will lockout in the open position without sounding the alarm. Press the STOP button to release the lockout. OPERATOR #1 OPERATOR #2 USE BELDEN 8760 TWISTED PAIRSHIELDED CABLE OR EQUIVALENT SHIELD CONNECT SHIELD WIRE AT BOTH ENDSDUAL GATE COMM LINK WIRINGCONNECT C - C B -BA - A SHIELD Figure 14. COMM LINK Wiring Open Input Functions the same as the OPEN button. Open Obstruction While the gate opening, any open obstruction signal will cause the gate to stop, reverse a short distance, and then stop again. The Auto Close Timer will be disabled, and a renewed input will be required to start the gate again. Should the gate be restarted and the obstacle signal occur again prior to reaching a limit, the gate will stop again, lockou...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - SWC (1.02 mb)
Safety Gate - SWD (1.02 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien