Anleitung Zusammenfassung


Safe-T-Beam® System must be installed to close door. Homelink® and Car2U® compatible. For Answers and Assistance: 1.800.354.3643 or visit WARNING: To reduce the risk of injury to persons or damage to property – Use this opener only with a one piece or sectional door. SAVE THIS MANUAL FOR FUTURE REFERENCE. INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. Genie, Genie logo, Intellicode and Safe-T-Beam are registered trademarks and TriloG is a trademark of GMI holdings, Inc., dba The Genie Company. Homelink® is a registered trademark of Johnson Controls Technology Company. Car2U® is a registered trademark of Lear Corporation. © 2010 The Genie Company PN# 37064500118, 12/2010 PN# 37026500017, 3/30/2009 SAFETY INFORMATION OVERVIEW OF POTENTIAL HAZARDS READ THIS SAFETY INFORMATION CONVENTIONS USED IN THESE INSTRUCTIONS Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call your nearest trained door system technician or visit our website. The following Safety Alert symbol and signal words are used throughout this manual to call attention to and identify different levels of hazard and special instructions. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word "DANGER", "WARNING", or "CAUTION" DANGER indicates an imminently hazardous situation which, if NOT avoided, will result in death or serious injury. WARNING indicates a potentially hazardous situation which, if NOT avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if NOT avoided, may result in injury or property damage. The word NOTE is used to indicate important steps to be followed or important considerations. IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Potential Hazard Effect Prevention WARNING Could result in Death or Serious Injury Keep people clear of opening while Door is moving. Do NOT allow children to play with the Door Opener. Do NOT operate a Door that jams or one that has a broken spring. Turn OFF power before removing opener cover. When replacing cover, make sure wires are NOT pinched or near moving parts. Opener must be fully grounded. Do NOT try to remove, install, repair or adjust springs or anything to which door spring parts are fastened, such as, wood blocks, steel brackets, cables or other like items. Installations, repairs and adjustments must be done by a trained door system technician using proper tools and instructions. WARNING Could result in Death or Serious Injury WARNING Could result in Death or Serious Injury ©2010 The Genie Company 12/2010 OPENER FEATURES INTELLICODE® 2 Access Security System A new generation superior encryption system that enhances the security of the door opener by continuously changing the access code each time the remote is used. The door opener responds to each new code only once. An access code copied from a working system and tried again will not control the door opener. Wall Console, Series III Operates door opener from inside garage. The Wall Console has an Indicator Light with: Open/Close, Sure-Lock™, and Independent Light Control buttons. follow the HomeLink® or Car2U® instructions in your car owner’s manual. and Car2U® compatible. Refer to the programming instructions on page 10 and then SAFETY FEATURES Safe-T-Beam® (STB) Non-Contact Reversing System Puts an invisible beam across the door opening. The door stops and reverses to the full open position if anything passes through the beam. LED indicator lights on the powerhead and on the STBs provide a self diagnostic code if an operational problem exists. Safe-T-Reverse® Contact Reversing System Automatically stops and reverses a closing door within two seconds of contact with an object. Automatic ForceGuard™ Control Automatically sets the force required to fully open and close the door for maximum safety. Watch Dog™ Monitoring System Monitors the Safe-T-Beam® system to ensure proper functionality and will automatically stop and reverse a closing door if a problem is detected. Manual Emergency Release Manually releases door from door opener. Used during a power failure or other emergency to allow manual opening and closing of door. SmartSet™ Electronic Programming Easily adjust the programming to reduce opening speed to a desired rate, vary limits and force, and program new remotes. Automatic Lighting System Two bulb lighting system supplies up to 200 Watts of light for safer evening exits and entries. Turns ON when door is activated and automatically turns OFF 4 minutes later. Integrated Motion Detection (...

Dieses Handbuch ist für folgende Modelle:
Safety Gate - TRILOG 3064H (5.83 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien