Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung SkyLink, modell GT-100

Hersteller: SkyLink
Dateigröße: 88.13 kb
Dateiname: 73106.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


INSTALLATION (CONT) Congratulations on your purchase of the Skylink® Garage Door Closer Model GT-100. Skylink® Garage Door Closer is very easy to install, and provides you with the peace of mind you have been looking for by knowing your garage door will not be left open anymore. Skylink® Garage Door Closer consists of 2 units: Garage Door MonitorTM Sensor (Battery Included) GS-101 3V Lithium battery 4 pcs 3 x 18 screws Double-sided foam tape Wall Console 2 pcs 3.5 x 25 screws Extension wires GT-100R Wall Console does not require any battery to operate and it can replace most of the existing garage door opener’s push buttons. Garage Door Sensor is battery operated and can be mounted on to the garage door by double sided tape or screws. These 2 units operate wirelessly which simplifies the installation. Programming is very simple, you can select the time you would like the door to be closed after it has been opened. The selectable door closing times are 2 minutes, 5 minutes, 10 minutes and 20 minutes. WARNING Before installing the Skylink® garage door closer, ensure your garage door is equipped with an external entrapment protection device, such as an infrared beam sensor which “sees” an object obstructing the door without having actual contact with the object. A Garage door opener does that not have the auto reversing mechanism should be replaced by one that has the auto reversing mechanism feature and the garage door closer must not be installed on garage a door opener without this feature. Without a properly working safety reversal system, a person could be seriously injured or killed by a closing garage door. 2. INSTALLATION WARNING Unplug the power cord of your garage door opener before installation to ensure power is not connected. The installation involves 2 units: 1) Garage Door MonitorTM Sensor 2) Wall Console Garage Door MonitorTM Sensor Step 1 – Select a spot on your garage door to mount the sensor Before you install the sensor onto the garage door, make sure the garage door is closed. The sensor Remove the battery assembly should be mounted on one of the vertical isolator supports of your garage door near the bottom. When the door is closed, the detection rod should be retracted. When the door is open, the detection rod will be extended. Door closed Door open One of Vertical Supports Step 2 – Mount the sensor on to your garage door 4 Screws You can mount the sensor onto your garage door with double-sided foam tape if the surface of your garage door is smooth and clean enough to provide a good adhesive surface, such surface can usually be found on a metal garage door. Please ensure the surface is Double-sidedsmooth and clean. Important: The bottom foam tapeof the sensor should be 1/2 inch above the ground. (Refer to Diagram A) For w ooden garage doors, it is recommended to mount the sensor with screws on to the garage door with 3 x 18 screws provided. Note: When the garage door is opening/closing, make sure the sensor does not interfere with the safety reversing sensor or safety beam sensor supplied with your existing garage door opener. 1/2 Inch Note: Ensure you straighten up the antenna on the receiver to receive the best possible Diagram A reception. Wall Console The GT-100R Wall Console replaces most garage door “push buttons” or “wall consoles”. There are 2 different kinds of “push buttons”. 1) Single button 2) Multi-Function Wall Console 1) Single button If your garage door opener equips with a single button “push button”, you can replace the existing push button with Skylink® Garage Door Closer Wall Console GT-100R. Please follow the procedures below. 1. Remove the existing push button by removing the screws. 2. Disconnect the 2 wires that are connected to Remove the existing push button. existing wires 3. Connect these 2 wires to the 2 terminals on the GT-100R Wall Console. Loosen the 2 screws on the terminals, feed the 2 wires to the 2 terminals and tighten 2 screws to secure the 2 wires. 4. After connecting the 2 wires, the red LED underneath the push button will be on. The GT-100R is now charging up. The GT-100R will be fully charged when the buzzer emits a beep (approx 10 seconds to 1 minute depending on the brand of garage door opener), the red LED will then flash slowly. The GT-100R is now ready to operate. 5. Mount the Wall Console to the wall with 2 screws. 6. Straighten up the antenna on the GT-100R. 2. INSTALLATION (CONT) 3. OPERATION 2. INSTALLATION (CONT) 3. OPERATION 2) Multi-Function Wall Console Multi-Function Wall Console normally comes with 3 buttons that can be used to: 1) operate the garage door opener lighting, 2) lock the receiver so it doesn’t accept remote control operation, and 3) push button for door opening / closing Depending on the brand of garage door opener you have, the installation is different. Multi-Function Wall Console for Chamberlain®, Lift-Master®, Sears Craftsman® Skylink® GT-100R Wall Console also has 3 buttons. It can replace Chamberlain®, Lift-Maste...

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien