Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Crestron electronic, modell Pre-Construction Wall Mount Back Box BB-6X-DSW

Hersteller: Crestron electronic
Dateigröße: 655.16 kb
Dateiname: bb-6x-dsw.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


©2008 Crestron Electronics, Inc. Contents Pre-Construction Wall Mount Back Box: BB-6X-DSW 1 Description.................................................................................................................................1 Setup..........................................................................................................................................5 Assembly.....................................................................................................................5 Mounting.....................................................................................................................5 Installation...................................................................................................................7 Other Mounting Option Accessories...........................................................................8 Resources...................................................................................................................................9 Industry Compliance...................................................................................................9 Reference Documents..................................................................................................9 Further Inquiries..........................................................................................................9 Future Updates............................................................................................................9 Return and Warranty Policies..................................................................................................10 Merchandise Returns / Repair Service......................................................................10 CRESTRON Limited Warranty.................................................................................10 Pre-Construction Wall Mount Back Box: BB-6X-DSW Description The Crestron® BB-6X-DSW back box provides a UL®-listed, recess-mounted steel enclosure for the TPS-6X-DSW Wall Mount Docking Station. Designed for pre- construction applications, the BB-6X-DSW permits fastening to the left or right side of a stud in a framed wall prior to installation of sheet rock. Conduit knockouts are provided on the top and bottom to accommodate a variety of fittings and a blank cover plate is included. NOTE: If mounting into a material other than drywall (for example, wood lectern, concrete or rock) use the cutout template, available in the post-construction kit MMK-6X-DSW or TMK-6X-DSW. NOTE: For concrete and rock mounting material, allow for proper ventilation before mounting the TPS-6X-DSW. The table below lists all parts included with the BB-6X-DSW. Supplied Hardware for the BB-6X-DSW DESCRIPTION PART NUMBER QUANTITY Assembly, Wall Mount, Back Box 4507462 1 Metal, Plate, Blank, Cover 2022825 1 Screw, #06-32 x 1-.”, Pan, Phil 2007254 4 Screw, #08-8B, .”, Pan, Phil 2007277 1 The mounted view of the BB-6X-DSW is shown in the following illustration. BB-6X-DSW Mounted View (Optional Cover Plate Attached) The dimensions of the BB-6X-DSW are shown in the following illustration. BB-6X-DSW Overall Dimensions (Front View) 12.00 in(30.46 cm) 6.35 in(16.13 cm) 8.88 in(22.54 cm) 9.06 in(23.01 cm) 8.00 in(20.32 cm) 5 in(127 mm) 9 in(227 mm) 7 3/4 in(197 mm) 6 3/4 in(171 mm) 6 in(152 mm) 5 7/8 in(148 mm) 6 3/16 in(155 mm) 6 1/4 in158 mm) BB-6X-DSW Overall Dimensions (Bottom View) 3.25 in(8.25 cm) 10.50 in(26.65 cm) 3.31 in(8.41 cm) 1.50 in(3.81 cm) NOTE: Knockout holes are intended for Class 2 wiring only and are .” and .” diameter. BB-6X-DSW Overall Dimensions (Cover Plate) 0.03 in(0.08 cm) 7.00 in(17.78 cm) 9.85 in(25.02 cm) Setup Assembly Required Tools: • #2 Phillips tip screwdriver The back box mounting enclosure comes fully assembled except for a grounding screw. To prepare for mounting, complete the following procedure: 1. Remove knockouts as required. 2. Attach the supplied #08-8B self-tapping screw to back box mounting enclosure assembly for grounding. NOTE: The #08-8B self-tapping screw (2007277), supplied for grounding purposes, is installed in the rear of the back box mounting enclosure assembly. Mounting Required Tools and Materials: • #2 Phillips tip screwdriver • Level • Standard drywall screws or nails (not included) CAUTION: Allow an air gap of a least 12 inches (30.48 cm) in the wall cavity above and below the TPS-6X-DSW for heat dissipation. NOTE: If your installation is not on wooden studs, be sure to consider the needs of your particular situation. For example, screw type may vary for steel studs, etc. To mount the back box, complete the following procedure (refer to illustration on the following page). 1. Position the back box against the stud so the extended edge of the attached mounting plate covers the front edge of the stud. Be sure the side of the back box is also against the side of the stud. 2. Use the level and verify the back box is horizontal. Leveling must be done before proceeding. 3. Attach...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien