Anleitung Char-Broil, modell "REGAL"SERIES RADIANT CHAR-BROILERS, (RBA) RBA Series

Hersteller: Char-Broil
Dateigröße: 278 kb
Dateiname: dab61161-f36d-4386-83e3-06fe873026cb.pdf
Unterrichtssprache:enfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Range manufactures the “Regal” Char-Broiler (RBA) in widths from two to six feet, to be used either as freestanding counter units or built into either a “Cuisine” or “Performer” range. All broilers are shipped completely assembled, with the double drip pans and pressure regulator packed on top of the broiler. A piece of 2x4 lumber is strapped to the radiants to prevent vibration damage. All units are inspected at the factory before shipping. Uncrating After uncrating, immediately check the equipment for visible signs of shipping damage. If such damage has occurred, do not refuse shipment, but contact the shipper and file the appropriate freight claims. INSTALLATION Rating Plate The rating plate is attached to the right side of the appliance. When corresponding with the factory or your local authorized factory service center regarding service problems or replacement parts, be sure to refer to the particular unit by the correct model number (including the prefix and suffix letters and numbers) and the warranty serial number. The rating plate affixed to the unit contains this information. Other information on this plate is the BTU/hr input to the burners, outlet gas pressure in inches WC, and whether orificed for natural or propane gas. WARNING All U.S. Range char-broilers must be connected only to the type of gas identified on the rating plate! Clearances The appliance area must be kept free and clear of all combustibles. This unit is design-certified for the following installations: 1. For installation in non-combustible locations only. 2. For use only with four-inch high adjustable legs. 3. Zero clearance is required from non-combustible construction at sides and rear. Adequate clearances must be maintained at all times in front and at the sides of the appliance for servicing and proper operation. Positioning and Setup Place a carpenter’s spirit level left-to-right on the front landing ledge and across the back trim, and also front-toback on the right and left end trims. Level to the high corner with the screw adjustment built into the foot of each leg. Air Supply and Ventilation The area around the appliance must be kept clear to avoid any obstruction to the flow of combustion and ventilation air, as well as, for ease of maintenance, service and proper appliance operation. Keep proper clearances for adequate air supply. Means must be provided for any commercial, heavy-duty cooking appliance to exhaust combustion waste products to the outside of the building. This is doubly important for open-grate broilers, since the design promotes grease dripping through the grate onto the hot radiants, sending smoke back up through the product as flavor enhancement. “Regal” series char-broilers must be installed under a vent hood. Filters and drip troughs should be part of any industrial hood, but consult local codes before construction and installation. Air movement should be checked during installation. Strong exhaust fans in the hood or in the overall air conditioning system can produce a slight vacuum in the room and/or cause air drafts. These can interfere with pilot or burner performance and can be hard to diagnose. If pilot or burner outage problems persist, make-up air openings or baffles may have to be provided in the room. If pilot/burner outage problems persist make-up air openings or baffles may have to be provided in the room. Page 4 Part # 1382692 Rev 3 (02/22/08) INSTALLATION Continued Standards Installation must be planned in accordance with all applicable state and local codes, taking into account the following standards (or latest edition): Grease Extractor ANSI/NFPA 96-1992 Power Ventilators ANSI/NFPA 96-1987 Filter Unit ANSI/NFPA 96-1987 Smoke Detectors ANSI/NFPA 728-1986. CAN/ULC 8553 1986 Fire Extinguisher (C02) ANSI/NFPA 12-1989 This section is not intended to be complete and other nationally recognized standards may be appropriate. Gas Supply 1. Installation of the equipment should be made by a licensed plumber. 2. A gas shut-off valve must be installed in the gas supply line ahead or the appliance for safety and for ease of future service. 3. A gas pressure regulator must be installed at the appliance prior to connecting the equipment to the gas line. Failure to install a regulator will void the equipment warranty. NO...

Dieses Handbuch ist für folgende Modelle:
Konvektionsöfen - "REGAL"SERIES RADIANT CHAR-BROILERS, (RBA) RBA Series (278 kb)
Konvektionsöfen - "REGAL"SERIES RADIANT CHAR-BROILERS, (RBA) RBA Series (278 kb)
Konvektionsöfen - "REGAL"SERIES RADIANT CHAR-BROILERS, (RBA) RBA Series (278 kb)
Konvektionsöfen - "REGAL"SERIES RADIANT CHAR-BROILERS, (RBA) RBA Series (278 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien