Anleitung Brinkmann, modell 7625
Hersteller: Brinkmann Dateigröße: 1.31 mb Dateiname: 826794f6-7827-46e9-a310-9c3d0e40fe21.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
• FOR OUTDOOR USE ONLY. DO NOT operate indoors or in an enclosed area such as a garage, shed or breezeway. • Use your grill OUTDOORS in a well ventilated space away from dwellings or other buildings to prevent dangers associated with gas accumulation and toxic vapors. We recommend your grill be situated at least 10 feet (3.1 m) from buildings. • Maintain a minimum clearance of 36 inches (91 cm) between all sides of grill and walls or other combustible material. DO NOT use grill under overhead unprotected combustible construction. • DO NOT use or install this grill in or on a recreational vehicle and/or boat. INSTALLATION INFORMATION: The installation of this appliance must be in accordance with: All applicable local codes, or in the absence of local codes, either: • National Fuel Gas Code ANSI Z223.1 NFPA 54 • Natural Gas and Propane Installation Code: CAN/CGA B149.1 • Natural Gas Installation Code: CAN/CGA B149.1 (Canada) • Propane Installation Code: CAN/CGA B149.2 (Canada) To check your local codes, see your local LP gas dealer or natural gas company. This grill was not intended to be connected to a natural gas supply line. If an external electrical source is utilized, it must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA 22.1. WARNING LP GAS CYLINDER (NOT SUPPLIED WITH THIS GRILL) The LP cylinder is available for purchase at the same location the grill was purchased. The LP (Liquid Propane) gas cylinder specifically designed to be used with this grill must have a 20 lb. (9.1 kg) capacity incorporating a Type 1 cylinder valve and an over-filling protection device (OPD). • DO NOT connect this grill to an existing #510 POL cylinder valve with Left Hand threads. The Type 1 valve can be identified with the large external threads on the valve outlet. • DO NOT connect to a propane cylinder exceeding this capacity. • DO NOT connect to a cylinder that uses any other type of valve connection device. CYLINDER SPECIFICATIONS: When purchasing or exchanging a cylinder for your gas grill, it must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339 Cylinders, Spheres and Tubes for Transportation of Dangerous Goods; and Commission, as applicable; and provided with a listed over-filling prevention device (OPD), and provided with a cylinder connection device compatible with the connection for outdoor cooking appliances. The cylinder must also be equipped with: • A shut-off valve terminating in a Type 1 gas cylinder valve outlet. • A Type 1 valve that prevents gas flow until a positive seal is obtained. • An arrangement for vapor withdrawal. • A collar to protect the cylinder shut-off valve. • A safety relief device having direct communication with the vapor space of the cylinder. • A listed over-filling prevention device (OPD). • Turn off the cylinder valve when your grill is not in use. • Handle the tank with care. • Always secure the cylinder in an upright position. • Never connect an unregulated LP gas cylinder to your grill. • DO NOT expose LP gas cylinders to excessive heat or ignition sources. • DO NOT store a spare LP gas cylinder under or near your grill. • Allow only qualified LP gas dealers to fill or repair your LP gas cylinder. • DO NOT allow the cylinder to be filled beyond 80% capacity. • Read and follow all warnings and instructions that are on the cylinder and that accompany this product. • Never store a spare LP gas cylinder under or near your grill. This could cause excess pressure to be expelled through the vapor relief valve resulting in fire, explosion, or severe personal injury including death. Note: Propane gas is heavier than air and will collect in low areas. Proper ventilation is extremely important. • Keep the ventilation opening(s) of the LP gas cylinder enclosure free and clear from obstructions and debris. • DO NOT insert any foreign objects into the valve outlet. Damage to the back-check could result. A damaged back-check can cause a leak, possibly resulting in explosion, fire, severe bodily harm, or death. WARNING DANGER FILLING THE LP GAS CYLINDER: • Allow only qualified LP gas dealers to properly fill or repair your LP gas cylinder. • New tanks should be purged prior to filling; inform LP gas dealer if you are using a new tank. • DO NOT allow the cylinder to be filled beyond 80% capacity. Over-filled tanks can create a dangerous condition. Over-filled tanks can build-up pressure and cause the relief valve to expel propane gas vapors. The vapor is combustible and if it comes in contact with a spark source or flame an explosion causing severe burns, bodily harm, or death could occur. • Always use a protective cylinder cap when grill is not connected to cylinder. • If you exchange a cylinder with a qualified exchange program, be sure the...