Login:
Stimmen - , Durchschnittliche Bewertung: ( )

Anleitung Beckett, modell CF2500

Hersteller: Beckett
Dateigröße: 2.84 mb
Dateiname: 6104BCF35.pdf

Unterrichtssprache:en

Das Dokument wird geladen, bitte warten
Das Dokument wird geladen, bitte warten

Anleitung Zusammenfassung


Save this manual for future reference. ...... Incorrect installation, adjustment, or misuse of this burner could result in death, severepersonal injury, or substantial property damage. To the Professional, Qualified Installer or Service Agency: Please read and carefully follow all instructions provided in this manual before installing, starting, or servicing this burner or heating system. The Installation must be made in accordance with all state and local codes having jurisdiction. .... COMMERCIAL PRODUCTS Potential for Fire, Smoke and Asphyxiation Hazards To the Homeowner or Equipment Owner: Please read and carefully follow all instructions provided in this manual regarding your responsibilities in caring for your heating equipment. Contact a professional, qualified service agency for installation, start-up or service work. Save this manual for future reference. ...... Incorrect installation, adjustment, or misuse of this burner could result in death, severepersonal injury, or substantial property damage. To the Professional, Qualified Installer or Service Agency: Please read and carefully follow all instructions provided in this manual before installing, starting, or servicing this burner or heating system. The Installation must be made in accordance with all state and local codes having jurisdiction. .... To the Owner: Thank you for purchasing a Beckett burner for use with your heating appliance. Please pay attention to the Safety Warnings contained within this instruction manual. Keep this manual for your records and provide it to your qualified service agency for use in professionally setting up and maintaining your oil burner. Your Beckett burner will provide years of effi cient operation if it is professionally installed and maintained by a qualified service technician. If at any time the burner does not appear to be operating properly, immediately contact your qualified service agency for consultation. We recommend annual inspection/service of your oil heating system by a qualified service agency. Daily – Check the room in which your burner/appliance is installed. Make sure: Air ventilation openings are clean and unobstructed Nothing is blocking burner inlet air openings No combustible materials are stored near the heating appliance There are no signs of oil or water leaking around the burner or appliance Weekly - Check your oil tank level. Always keep your oil tank full, especially during the summer, in order to prevent condensation of moisture on the inside surface of the tank. Special Requirements - The installation of a burner shall be in accordance with the regulations of authorities having Jurisdiction. 0 For recommended installation practices in the U.S. refer to the latest edition of NFPA 31. (CSA-B139 and CSA-B140 in Canada. Impaired Burner Performance & Fire Hazard Do NOT operate the burner beyond specifications outlined in the Table on Page 3. • For applications beyond these limits, consult Beckett Technical Services at 1-800-645-2876. • NOTE: Some packaged appliances with burners may be agency listed as a unit to operate beyond these limits. Consult the appliance manufacturer’s specifications and agency approvals for verification. Contents General Information ....................................................3 Hazard Defi nitions .........................................................................3 Specifi cations ................................................................................3 Owner’s Responsibility: .................................................................3 Service Agency Responsibility: .....................................................3 Combustion Air Supply ..................................................................4 Clearances ....................................................................................4 Fuel Supply ...................................................................................4 Nozzle Pressure ............................................................................5 Electrical Supply ............................................................................5 Vent System ..................................................................................5 Verify Burner Components ............................................................5 Verify Firing Rate ...........................................................................5 Verify Air Tube ...............................................................................6 Dust and Moisture .........................................................................7 Mount the Burner .........................................................7 Mount Flange(s) on Air Tube .........................................................7 Mount Air Tube to Burner ..............................................................8 Install Nozzle .................................................................................8 Check Electrode Settings ......................

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien