Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.3 ( )

Anleitung Beckett, modell 120 Vac/60 Hz

Hersteller: Beckett
Dateigröße: 1.51 mb
Dateiname: befb503d-3e8e-4165-a2d2-3940e748aadd.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3 Be aware of hazard definitions ........................................................................... 3 Check certifications/approvals ........................................................................... 3 Notice special requirements................................................................................ 3 Prepare burner & site Inspect/prepare installation site .......................................................................... 4 Prepare burner ..................................................................................................... 5 Check/adjust “Z” dimension ............................................................................... 6 Set head position adjusting plate (“V1” head only) ............................................ 7 Adjust, pipe & wire burner Mount burner on appliance................................................................................. 8 Connect fuel lines ................................................................................................ 8 Wire burner .......................................................................................................... 8 Startup & adjust burner Startup burner/set combustion......................................................................... 10 Set combustion with instruments ..................................................................... 10 Service & maintain burner Perform annual maintenance............................................................................ 10 To replace the blower wheel ............................................................................. 10 Replacement parts ............................................................................................. 11 Owner’s information and warranty ................................................................... 12 Table 1 — Air tube combination (ATC) codes* Instruction Manual – Model AFG Oil Burner 3 Be aware of hazard definitions Denotes presence of a hazard which, if ignored, will result in severe personal injury, death or substantial property damage. Denotes presence of a hazard which, if ignored, could result in severe personal injury, death or substantial property damage. Denotes presence of a hazard which, if ignored, could result in minor personal injury or property damage. Intended to bring special attention to information, but not related to personal injury or property damage. Notice special requirements This equipment must be installed, adjusted and started only by a – an individual or agency, licensed and experienced with all codes and ordinances, who is responsible for the installation and adjustment of the equipment. The installation must comply with all local codes and ordinances and with the latest revision of the National Fire Protection Standard for Oil-Burning Equipment, NFPA 31 (or CSA B139-M91). . Follow all instructions completely. Failure to follow these instructions could result in equipment malfunction, causing severe personal injury, death or substantial property damage. Concealed damage — If you discover damage to the burner or controls during unpacking, notify the carrier at once and file the appropriate claim. When contacting Beckett for service information — Please record the burner serial number (and have available when calling or writing). You will find the serial number on the Underwriters Laboratories label, located on the left rear of the burner, or the cover mounting plate. See illustration below. Check certifications/approvals • Underwriters Laboratorieshas certified this burner to comply with ANSI/UL 296 and has listed it for use with #1 or #2 fuel oil as specified in ASTM D396. Low sulfur #1 and #2 fuel oils reduce heat exchanger deposits with all burners compared to the standard fuels. Reduced deposits extend the service interval for cleaning and improve the efficiency of the appliance over time. Low sulfur fuels reduce particulate and oxides of nitrogen emissions as well. The Oilheat Manufacturers' Association recommends these fuels as the preferred fuels for this burner. • State and local approvals are shown on burner rating label (see below). • All oil burners should be installed in accordance with regulations of the latest revision of the National Fire Protection AssociationStandard NFPA 31 and in complete accordance with all local codes and authorities having jurisdiction. Regulation of these authorities take precedence over the general instructions provided in this installation manual. • For recommended installation practice in Canada, reference to CSA Standard B139-M91. Prepare before installing Verify specifications Instruction Manual – Model AFG Oil Burner Prepare burner & site Inspect/prepare installation site Chimney or vent • Inspect the chimney or vent, making sure it is properly sized and in good condition for use. • For those installations not requiring a chimney, such as through-the-wall vented appliances, follow the instruct...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien