|
Anleitung Zusammenfassung
If damage is detected when the equipment is uncrated, immediately call the delivering truck line and follow up the call with a written report indicating concealed damage to your equipment. Ask for an immediate inspection of your concealed damage item. Crating material MUST be retained to show the inspector from the truck line. Electrical Information And Grounding Electrocution, equipment failure or property damage could result if an unlicensed electrician performs the electrical installation. Ensure that a licensed electrician perform the electrical installation in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI NFPA 70-20XX. This unit, when installed by an authorized BKI service agent, must be wired for use in accordance with all applicable local, state, and federal codes. For specific electrical requirements and connections refer to the wiring diagram attached to the unit or provided in the Service Manual. Installation Instructions Right-Sided SFW 1. Obtain a suitable countertop location and place the entire unit in position. 2. Measure, mark and cut a hole in the countertop for the Fry Warmer blower pan to fit in according to the following drawing. 9 Sandwich/Fry Warmer Installation 3. Place the blower pan into the hole making sure that open side of the pan fits over the two tabs on the louvered blower box. 4. Place the perforated pan insert into the blower pan. Left-Sided SFW 1. Obtain a suitable countertop location and place the entire unit in position. 2. Measure, mark and cut a hole in the countertop for the Fry Warmer blower pan to fit in according to the following drawing. 3. Place the blower pan into the hole making sure that open side of the pan fits over the two tabs on the louvered blower box. 4. Place the perforated pan insert into the blower pan. 10 Sandwich/Fry Warmer Installation FW-15L 1. Obtain a suitable countertop location for the unit that will provide a clearance of 4” from the side louvers. 2. Cut a hole in the countertop to fit the collar weldment according to the drawing below. 3. Using a 2” hole saw, drill a hole in the countertop (under where the louvered blower box will be positioned) for the power cord to pass through. 4. Position collar weldment into the cutout area with slotted holes toward the main unit. 5. Position the main unit as shown above ensuring that the side panel flanges are under the flanges of the collar weldment. 6. Line up the back attachment holes on the flanges of the main unit with the slotted holes in the flanges of the collar weldment. 7. Remove the louvered blower box to access the front attachment holes by unscrewing 7 screws shown below. 11 Sandwich/Fry Warmer Installation 8. Using a 1/8” drill bit, drill holes in countertop through existing holes in the main unit and collar weldment flanges. 9. Secure main unit and collar weldment to countertop using #8 sheet metal screws. 10. Feed power cord (supplied), down through hole in countertop. 11. Reattach louvered blower box to main unit. 12. Seal main unit to the countertop to conform to NSF Standard 4, Item 4.28. (Dow Corning RTV #732 Multi purpose Sealant.) 13. Place the blower pan into the hole making sure that open side of the pan fits over the two tabs on the louvered blower box. 14. Place the perforated pan insert into the blower pan. 12 Sandwich/Fry Warmer Maintenance Maintenance Failure to comply with the maintenance below could result in a serious accident. Electrocution, equipment failure or property damage could result if an unlicensed electrician performs electrical repair. Ensure that a licensed electrician perform electrical repair. Scheduled Maintenance This unit should be cleaned at the end of each working day. Use the following procedure: Failure to remove power from this unit may cause severe electrical shock. This unit may have more than one disconnect switch. Never use abrasive cleaners that may damage the finish. Never steam clean the interior. Avoid getting excess water in the interior of the unit. Do not clean the heater/blower assembly by applying compressed air. Do not leave this unit on and unattended after business hours. SFW Cleaning 1. Remove all food from the unit. 2. Place the Fry Warmer ON/OFF switch to the OFF (0) position. 3. Place the Sandwich Warmer POWER ON/OFF switch to the OFF (0) position. 4. Unplug both power cords. 5. Allow the equipment to cool to room temperature. 6. Remove and clean the Fry Warmer blower pan and pan insert. 7. Clean around the slotted holes at the air discharge on the blower box. 8. Clean the air intakes using a mild soap and water solution. 9. Sponge the inside and outside of the unit with a mild soap and water solution, being sure to clean all areas. Avoid getting water in the interior of the unit. 10. Wipe the parts and unit dry with a soft, clean cloth and replace the blower pan and pan insert. FW-15L Cleaning 1. Remove all food from the unit. 2. Place the Fry Warmer ON/OFF switch to the ...
Dieses Handbuch ist für folgende Modelle:Konvektionsöfen - Sandwich/Fry Warmer FW-15L (860.58 kb)