Anleitung Zusammenfassung


Pilot should remain lit. If it goes out, repeat steps 4 through 8. . If knob does not pop up when released, stop and immediately call your qualified service technician or gas supplier. . If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier. 9. Turn gas control knob counterclockwise to "ON." 10. Set the ON/OFF switch to "ON". 14015-1-0903 Page 11 PILOT AND MAIN BURNER FLAME CHARACTERISTICS PILOT AND MAIN BURNER FLAME CHARACTERISTICS Pilot Flame Pattern (Figure 9) Figure 8 shows a correct pilot flame pattern. The correct flame will be blue and will extend beyond the thermocouple/thermopile. The flame will surround the thermocouple/thermopile just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. After use, cleaning of the pilot burner may be required for the proper flame. The pilot orifice can be cleaned with high pressure air or by placing under running water. Pilot orifice must be dry before replacement. Use a pipe cleaner to clean inside the pilot after the pilot orifice has been removed. To Remove Pilot Orifice 1. Disconnect the pilot supply line at the pilot burner. 2. Remove pilot orifice from pilot burner. It may be necessary to tap on pilot burner in order to remove the pilot orifice. Pilot Flame Pattern Figure 9 If pilot flame pattern is incorrect . See Troubleshooting, page 15 Main Burner Flame Pattern The main burner flame will be completely yellow. Main Burner Flame Ignition and Extinction When the main burner is ignited it will take a few seconds for the full flame pattern to develop. When the main burner is extinguished it will take a few seconds for the flames to disappear. It is normal to have the flames burn down near the rock wool, as the remaining gas is burned. Page 12 14015-1-0903 WIRING WIRING Thermostats are not approved on vented decorated appliances. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. VSR gas valve does not require 24 or 110 volts. See Figure 10 to provide optional wall switch or remote control. Maximum length of 20 feet of 16 AWG to conductor wires is to be used with all optional switches. Use the two leads (black wires) from ON/OFF switch to attach optional components. Check System Operation Millivolt system and all individual components may be checked with a millivolt meter 0-1000 MV range. 750 Millivolt System When you ignite the pilot, the thermocouple produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical current) to buildup to a sufficient level allowing the gas control to operate properly. Millivolt Control The valve regulator controls the burner pressure which should be checked at the pressure test point. Turn captured screw counter clockwise 2 or 3 turns and then place tubing to pressure gauge over test point (Use test point .A. closest to control knob). After taking pressure reading, be sure and turn captured screw clockwise firmly to re-seal. Do not over torque. Check for gas leaks. Remote Receiver -VSR-(18, 24, 30) Use the following steps to place the remote receiver adjacent to the gas valve. Attention: 1. The remote receiver can not be placed behind the gas valve and burner assembly. 2. When facing the appliance, the remote receiver must be placed in the right side firebox, toward the front. Note: Do not let remote control receiver come in contact with burner assembly. Refer to remote control installation and operating instructions for more details on remote control. VSR Wiring Diagram (Figure 10) Figure 10 VSR Note: (Wiring harness located in envelope) Connect the 2 - 1/4" terminals onto the TH and TH/TP terminals on valve. Place decorative log to right of the gas valve and burner assembly. When connecting to remote receiver, cut off 1/4" terminals from wires attached to ON/OFF switch. Strip wires back about 1/4". Connect stripped ends into remote receiver. CLEANING AND SERVICING Keep the control compartment, logs and burner area surrounding the logs clean. THE LOGS CAN GET VERY HOT. HANDLE ONLY WHEN COOL. Always keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids. Never obstruct the flow of combustion and ventilation air. Keep the front of the appliance clear of all obstacles and materials. 14015-1-0903 Inspecting Venting System A vented fireplace venting system is designed and constructed to develop a positive flow adequate to remove flue gases to the outside atmosphere. Any foreign objects in the venting system, ...

Dieses Handbuch ist für folgende Modelle:
Konvektionsöfen - VSM-18-1 (1.04 mb)
Konvektionsöfen - VSM-24-1 (1.04 mb)
Konvektionsöfen - VSM-30-1 (1.04 mb)
Konvektionsöfen - VSR-18-1 (1.04 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien