|
Anleitung Zusammenfassung
DANGERIMPROPERINSTALLATION, ALTERATION,ADJUSTMENT, SERVICE,ORMAINTENANCECOULDRESULTINSEVEREINJURY,DEATHORCAUSEPROPERTYDAMAGE. READTHEINSTALLATION, OPERATINGANDMAINTENANCEINSTRUCTIONSTHOROUGHLYBEFOREINSTALLINGORSERVICINGTHISEQUIPMENT. CAUTIONTOPREVENTPERSONALINJURY, USECAUTIONWHENMOVINGORLEVELINGTHISAPPLIANCE. SITEINSTALLATION In order to maintain established National Sanitation Foundation standards, all stationary floor modelsmust be sealed to the floor with a R.T.V. or silastic meeting N.S.F. requirements orhave 6" (152mm) unobstructed clearance beneath the unit. 1. The appliance mustbe installed on a ® stable and level surface. 2. DO NOT install this appliance in any area where itmay be affected by any adverse conditions such assteam, grease, dripping water, high temperatures, orany other severely adverse conditions. 3. DO NOT install a heated display case near a cold airsource such as a freezer, air conditioning vents, orin any area where outside air fluctuation canaffect performance. 4. This appliance must be kept free and clear ofany obstructions blocking access for maintenanceor service. 5. Care must be taken when moving this unit intoplace because of its glass components. A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs. LEVELING Level the appliance from side-to-side and front-to-back with the use of a spirit level. We recommend checking the level periodically to make certain the floor has not shifted nor the appliance moved. NOTE: Failure to properly level this appliance can cause improper function. CC Series Operation & Care Manual • 3 I N S TA L L AT I O N S I T E I N S TA L L AT I O N CC SERIES 30-5/16" (770mm) (499mm) 19-5/8" 4" ( 102mm) ( 102mm) 4" 51- 1/ 16" ( 1296mm) 51- 1/ 16" ( 1296mm) 20- 3/ 8" ( 518mm) Electrical Inlet Electrical Inlet 3" (76mm) CC-48 33-11/16" (855mm) 48-1/8" (1222mm) CC PROFILE Electrical Inlet 3" (76mm) CC-72 72-1/8" (1831mm) CC SERIES OPTIONS & ACCESSORIES DESCRIPTION CC-48 CC-72 GLASS, TEMPERED END PANE, BRONZE KIT 5009056 5009056 PANEL KIT STAINLESS STEEL CUSTOM COLOR 5009154 P141 5009155 P142 THERMOSTAT, DIGITAL AMBIENT TEMPERATURE (SOLAR POWERED) 14990 14990 WIRE SHELF GRID, STAINLESS STEEL UPPER TIER LOWER TIER SH-24144 (2 REQ’D) SH-24144 (3 REQ’D) SH-24145 (2 REQ’D) SH-24145 (3 REQ’D) CC Series Operation & Care Manual • 4 INSTALLATIONELECTRICALCONNECTIONINSTALLATIONELECTRICALCONNECTION DANGERELECTRICALCONNECTIONSMUSTBEMADEBYAQUALIFIEDSERVICETECHNICIANINACCORDANCEWITHAPPLICABLEELECTRICALCODES. DANGERToavoidelectricalshock,thisapplianceMUSTbeadequatelygroundedinaccordancewithlocalelectricalcodesor,intheabsenceoflocalcodes,withthecurrenteditionoftheNationalElectricalCodeANSI/NFPANo.70.InCanada,allelectricalconnectionsaretobemadeinaccordingwithCSAC22.1, CanadianElectricalCodePart1orlocalcodes. The appliance must be installed by a qualified service technician. The oven must be properly grounded in accordance with the National Electrical Code and applicable local codes. Plug the unit into a properly grounded receptacle ONLY, positioning the unit so that the plug is easily accessible in case of an emergency. Arcing will occur when connecting or disconnecting the unit unless all controls are in the “OFF” position. ELECTRICALCC-48VOLTAGEPHASECYCLE/HZAMPSkW208V(AGCY)150/60204.2NOCORD,NOPLUG150/60225.1150/6021.175.1PHASECYCLE/HZAMPSkW150/60306.2NOCORD,NOPLUG150/60337.5150/60317.5230V(AGCY) 240V(AGCY) CC-72VOLTAGE208V(AGCY) 230V(AGCY) 240V(AGCY) Proper receptacle or outlet configuration or permanent wiring for this unit must be installed by a licensed electrician in accordance with applicable local electrical codes. D A N G E R ENSURE POWER SOURCE MATCHES VOLTAGE STAMPED ON APPLIANCE NAMEPLATE. REGARDING INTERNATIONAL STANDARD UNITS: If the unit is not equipped with flexible cord with plug, an all-pole country approved disconnection device which has a contact separation of at least 3mm in all poles must be incorporated in the fixed wiring for disconnection. When using a cord without a plug, the green/yellow conductor shall be connected to the terminal which is marked with the ground symbol. If a plug is used, the socket outlet must be easily accessible. If the power cord needs replacement, use a similar one obtained from the distributor. For 230V units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an equalization-bonding stud is provided. An equalization bonding lead must be connected to this stud and the other appliances / metal parts to provide sufficient protection against potential difference. The terminal is marked with the following symbol. ...
Dieses Handbuch ist für folgende Modelle:Konvektionsöfen - CC-48 (683.69 kb)
Konvektionsöfen - CC-72 (683.69 kb)
Konvektionsöfen - CC-48 (683.69 kb)