Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Napoleon Fireplaces, modell GDIZC-P

Hersteller: Napoleon Fireplaces
Dateigröße: 2.9 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


We recommend that exhaust vents that pass through unheated spaces, such as a garage or attic, be wrapped in a protective sleeve to minimize condensa- tion and reverse flow symptoms. See Trouble Shooting for details. This unit is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance, however, it is recommended to use two 3" liners. If a 2" liner is used for the intake, it is necessary to adjust the primary air shutter. See "Air Shutter Settings" 4. Detach the two screws from the back of the firebox and remove the panel, as illustrated. FIGURE 4 VENT CONNECTOR EXTENSION RESTRICTOR PLATE STUDS 1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST & 2-3" TO 2" REDUCER: GDI-2320KT VENT KIT 20FT GDI-2325KT VENT KIT 25FT GDI-2335KT VENT KIT 35FT 2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST: GDI-320KT VENT KIT 20FT GDI-325KT VENT KIT 25 FT GDI-335KT VENT KIT 35 FT FIGURE5a-b 5. Reaching in through the insert, manoeuvre the vent connection assembly through the openings in the firebox top, taking care not to damage the gasket. In case of a low ceiling fireplace, the extension should be removed and reinstalled after the vent connection is secured to the firebox. Attach the restrictor plate to the centre stud and secure the assembly using the three studs and .-20 hex nuts. W415-0223 / D / 01.12.04 WALL SWITCH / THERMOSTAT GAS INSTALLATION FINISHING For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt thermostat. The recommended maximum lead length de pends on the wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Do not connect either the wall switch, thermostat or gas valve to electricity (110 VOLTS). Install suitable supply piping connection to the 3/8" flex connector supplied (as per local gas codes). FIGURE 6 The insert may now be pushed into its final position inside the wood-burning fireplace. Secure the insert to the fireplace using perforated strapping attached to the two securing holes on either side of the unit as shown. We recommend that the trim be installed before the unit is placed into its final position. SECURING HOLES FIGURE 7 In order to close off the fireplace opening or if the opening is larger than the 3- or 4-sided aluminium extrusion trim kits, it is recommended to reduce the opening using a noncombustible material such as ceramic tile, marble, etc or the GIZBP6-3 or GIZBP6-4 backer plate kits. The outside edge of the backer plate is finished off with gold trim included in each kit. A deluxe flashing kit complete with marquis trim may also be used to complete the installation. These flashing and trim combinations are available in 6 and 9 inch widths as well as many finishes to accent any room decor. Mounting brackets, GIZBRKT, are required to install the deluxe flashing. Detailed installation instructions are included with each kit. If this unit is being installed into an existing wood burning, zero clearance fireplace, then be aware of this precaution: Any circulation air opening may be covered (with noncombustible material) but not sealed! ALUMINIUM EXTRUSION TRIM KIT INSTALLATION The insert can be equipped with either a 3- or 4-sided trim kit to finish off the fireplace opening. Slide the trim assembly over the keyholes (2 per side) and drop into place. If installing the optional 3- or 4-sided backer plate (GIZBP6-3 or GIZBP64), it must be hung prior to the trim kit installation using the same keyholes. FIGURE 9 FIGURE 8 FIRE VIEWING DOOR FIGURE 11 VALVE CONTROL DOOR FIGURE 10 LOOSEN SCREWS SLIDE TO ADJUST To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made. Note: Since the side panels open and close, to access the controls, a gap is necessary at the mitre joint. The top trim piece has an adjustable securing bracket which enables the trim to be secured to the firebox shell. W415-0223 / D / 01.12.04 FIGURE 14 #4 LOG PLACEMENT DOOR INSTALLATION Positioning the logs improperly will cause flame im-Place the door into the two lower door brackets, and sepingement and carboning. cure at the top of the unit with two #10-24 machine screws. PHAZERTM logs and glowing embers, exclusive to Napoleon FIGURE 16 Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Use only certified PHAZERTM logs available from your Napoleon / Wolf Steel Ltd. dealer. 1. Place the rear log (#1) onto the two log supports and against the air intake pipe. LOWER DOOR BRACKET MANTLE CLEARANCE This can vary according to the mantle...

Dieses Handbuch ist für folgende Modelle:
Konvektionsöfen - GDIZC-N (2.9 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien