Hersteller: Frigidaire
Dateigröße: 361.5 kb
Dateiname: bcb2ec21-99ee-4853-aee6-1f93cc7105ee.pdf
|
Anleitung Zusammenfassung
This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder. L.P. Cylinders are not included with the grill. L.P. Cylinders can be purchased separately at an independent dealer. LP hose/ regulator supplied with head only grill. (Type 1 connector) LP hose/ regulator supplied with com plete grill and cart. (Type 1 connector) L.P. TANK INFORMATION Never use a dented or rusted L.P. tank or cylinder with a damaged valve. L.P. cylinders are equipped with an O.P.D (Overfilling Prevention Device). The device shuts off the flow of gas to a cylinder after 80% capacity is reached. This limits the potential for release of gas when the cylinder is heated, averting a fire or possible injury. The L.P. cylinder must have a shut-off valve terminating in an L.P. gas supply cylinder outlet specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building, garage, or any other enclosed area. (The L.P. cylinder must have an overfill protection device, OPD, on it.) The L.P. gas supply cylinder must be constructed and marked in accordance with the specifications for L.P. gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CAS-B339, “Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.” L.P. TANK USE • When turning the L.P. tank on, make sure to open the valve SLOWLY two (2) complete turns to insure proper gas flow. Most gas tanks now come equipped with a leak detector mechanism internal to the tank, when gas is allowed to escape rapidly it shuts off the gas supply. Opening the valve rapidly may simulate a gas leak, causing the safety device to activate, restricting gas flow causing low flames. Opening the valve slowly will insure this safety feature is not falsely triggered. • When not in use, gas supply cylinder valve is to be in the “OFF” position. • The tank supply system must be stored upright to allow for vapor withdrawal. • The regulator and hose assembly must be inspected before each use of the grill. If there is excessive abrasion or wear or if the hose is cut, it must be replaced prior to the grill being used again. • Cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other enclosed area. • Only a qualified gas supplier should refill the L.P. tank. • Do not store a spare L.P. gas cylinder under or near the grill. 10 Pre Operation Leak Testing GENERAL INFORMATION Although all gas connections on the grill are leak tested prior to shipment, a complete gas tightness check must be performed at the installation site due to possible shifting during shipment, installation or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks and immediately check the system if the smell of gas is detected. BEFORE TESTING Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Mix a solution of equal parts mild detergent or liquid soap and water. TESTING 1. Turn off the burner control knobs. 2. Turn the top knob of the fuel supply cylinder counterclockwise (right to left) two (2) rotations to open. 3. Apply the soap solution to connections of the fuel supply assembly. If no soap bubbles appear, there is no gas leak. If bubbles form at the connections, a leak is detected. If a leak is detected, immediately turn off the gas supply, tighten any leaking fittings, turn gas on, and repeat steps 1-3. 4. Turn off the knob on the fuel supply cylinder. 5. Turn on the burner control knobs for a moment to release the pressure in the hose, then turn the control knobs back off. 6. Wash off soapy solution with cold water and towel dry. Check all gas supply fittings before each use and each time the gas supply cylinder is connected to the regulator. Have a qualified service technician leak test the grill any time a part of the gas system is replaced. Also it is recommended to perform a leak test at least once a year whether or not the L.P. gas supply cylinder has been disconnected. NOTE: When leak testing this appliance, make sure to test and tighten all loose connections, including the side burner. A slight leak in the system can result in a low flame, or hazardous condition. Most L.P. gas tanks now come equipped with a leak detector mechanism internal to the tank, when gas is allowed to escape rapidly it shuts off the gas supply. A leak may significantly reduce the gas flow making the grill difficult to light or causing low flames. NOTE: If you cannot stop a gas leak turn off the gas supply and call your local gas company or the dealer you purchased the appliance from. If necessary, replace the faulty part with the manufacturer’s recommended replacement part. A slight leak could cause a fire. 11 Lighting the Grill BEFORE LIGHTING Important! Before Lighting... Check the gas supply line for cuts, wear or...