Login:
heruntergeladen wurde: 1   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

Refer to Figure 56. Receiver Shutdown of Burner • In the remote, auto mode the valve shuts off if it does not receive a signal within 3 hours from the transmitter • In the local mode the valve does not shut off • In the remote, manual mode the vavle shuts off if it does not receive a signal within 6 hours from the transmitter Thermopiles • The negative leads (white) must be connected to the terminals with the one white dot marked next to them • Each thermopile must provide at least 500 mV open c

heruntergeladen wurde: 2   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

• Check the ground lead from GND (BURNER) terminal on the module to the pilot burner. Make sure connections are clean and tight. If the wire is damaged or deteriorated, replace it with No. 14-18 gauge, moisture-resistant, thermoplastic insulated wire with 105 C (221 F) minimum rating. • If flame rod or bracket are bent out of position, restore to correct position. • Replace pilot burner/igniter sensor if insulator is cracked. Step 3: Checksparkignitioncircuit. Youwillneeda shortjumper wire made

heruntergeladen wurde: 7   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

When the internal beads of each starting outer pipe line up, rotate pipe section clockwise 90° (approximately 3 inches). The vent pipe is now locked together. Continue replacing components per the vent system configuration. Be certain that each succeeding vent component is securely fitted and locked into the preceding component in the vent system. Reassembly and Resealing Gas Accumulation Relief System Glass Frame Assembly and Combustion Chamber Whenever the glass frame assembly is pivoted open

heruntergeladen wurde: 4   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

Wall Switch, FWS-1 Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON switch wire harness to the wall switch. Turn the REMOTE/OFF/ON switch to the REMOTE position. Pivot the rocker switch on the FWS-1 to the ON position. Wall Thermostats (optional) TRW - Wireless for Millivolt models TMV - Reed switch for Millivolt models Battery Operated Remote Controls, FRBC, FBRTC, and TRW Connect the green and red, stripped and bare, wires on the REMOTE/OFF/ON switch wire harness to the

heruntergeladen wurde: 4   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

43 Maintenance and Service............................................................................................................. 44 Parts View...................................................................................................................................... 45 Parts List ....................................................................................................................................... 46 FBB4 Optional Variable Speed Blower Installation ..............

heruntergeladen wurde: 1   Dateigröße: 5 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name

. If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency, or the gas supplier. GAS-FIRED DIRECT VENT GAS FIREPLACE HEATER MODEL SERIES DVP42FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT) DVP48FP3(0,1,2,3)(N,P)-1 (MILLIVOLT STANDING PILOT) DVP42FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT) DVP48FP7(0,1,2,3)(N,P)-1 (INTERMITTENT PILOT) DVP42FP9(0,1,2,3)(N,P)-1 (REMOTE RF MODELS) DVP48FP9(0,1,2,3)(N,P)-1 (REM

heruntergeladen wurde: 0   Dateigröße: 3 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name@name

• An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom. • Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition. • Young children should be carefully supervised when they are in the same room with the appliance. • Do not place c

heruntergeladen wurde: 2   Dateigröße: 3 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name@name

(2.615kPa). Propane/LP gas will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0" w.c. (3.237kPa). A test gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch (3mm) N.P.T. plugged tapping. Recommended Gas Pipe Diameter Pipe Len

heruntergeladen wurde: 0   Dateigröße: 3 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name@name

USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. SR-10 PARTS VIEW SR-30 PARTS VIEW OPTIONAL BLOWER INSTALLATION INSTRUCTIONS (continued) Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protection against shock hazard and should be plugged direc

heruntergeladen wurde: 0   Dateigröße: 3 mb   Hersteller: Empire Comfort Systems  
Kategorie: Warmwasserbereiter
@name@name

If the manual gas control knob is in mid-position, between heat settings, incomplete combustion will take place, causing odor, and may produce gas leakage or carbon monoxide. 10. Turn on all electric power to appliance (if applicable). TO TURN OFF GAS TO APPLIANCE 1. Turn off all electric power to appliance if service is to be performed (if applicable). 2. Push in manual gas control knob slightly and turn clockwise to "OFF". Do not force. PILOT FLAME CHARACTERISTICS The correct flame will be blu