@name

Key Part Number Quantity* 3EZ 5EZ Description 1 1185026 1 -STRE-3 DOOR ASSEMBLY (see page 377 for individual parts) 1185122 -1 STRE-5 DOOR ASSEMBLY (see page 377 for individual parts) 2 1185016 1 1 DRIP PAN 3 1185115 1 -DOOR GASKET, STRE-3 1185135 -1 DOOR GASKET, STRE-5 4 1185072 1 1 DOOR SWITCH ASSEMBLY (see page 388 for individual parts) 5 1185036 1 1 FLOOR PANEL 6 1185103 1 -SIDEWALL ASSEMBLY STRE-3 1185123 -1 SIDEWALL ASSEMBLY STRE-5 7 1178668 1 -PAN GUIDE, LEFT SIDE, STRE-3 1178664 -1 PAN G

heruntergeladen wurde: 1   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

8. Repeat steps 5 through 7 with one test lead on terminal L3 of the contactor and the other test lead in position 2 of connector PL1 (as shown above). 9. Place one test lead on PL1 position 1 and the other test lead on PL1 position 2 (as shown above). Check for continuity with control lever in the ON position (there should not be continuity). 10. If continuity checks are incorrect, replace power switch. 11. Reconnect lead wires. OWNER’S MANUAL 1185184 PAGE 25 OF 44 SERVICE STRATOSTEAM COUNTERTO

heruntergeladen wurde: 0   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Check that steam is escaping from the vent at the top left rear corner of the steamer. 8. Move the ON/OFF lever to the “OFF” position and check that the Power light goes out. Also check that the water is draining correctly into the drain, and that the steamer completely drains. STEP 8: SHUT-DOWN AND WIPE-CLEAN STEAMER Complete the installation by leaving the steamer ready for customer use: 1. Allow the steamer to cool. 2. Wipe clean all surfaces. 3. Unless the steamer is to be placed in service

heruntergeladen wurde: 0   Dateigröße: 511 kb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Interior: Type 304 stainless steel. Legs: 4” stainless steel legs standard. Optional cabinet base available. Fully insulated cooking compartment. Power Source: Electric. One power source for controls and elements as well as one ground wire. A positive ground connection is essential. - ON/OFF Lever: Single switch for operation. When the amber Power light is illuminated this indicates the unit is on. - 60 Minute Timer: Time can be set between 1 and 60 minutes. When time expires, buzzer sounds

heruntergeladen wurde: 1   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Read this manual thoroughly before installing and operating this equipment. 1100 Old Honeycutt Road, Fuquay-Varina, NC 27526 MANUAL 1178387 REV 7 EZ COUNTERTOP STEAMERS $18.00 MANUAL SECTION ST MODEL EZ-3 & EZ-5 COUNTERTOP STEAMERS SAFETY PRECAUTIONS DANGER WARNING CAUTION NOTICE Before installing and operating this equipment, be sure everyone involved in its operation is fully trained and aware of precautions. Accidents and problems can be caused by failure to follow fundamental rules and preca

heruntergeladen wurde: 9   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

15, 2001, check and AT CIRCUIT BREAKER. Is “CHECK WATER LEVEL” light on with door closed? Check all main fuses or circuit breaker, replace as necessary. Unit not heating up properly, or not cooking as fast, “ON” light lit. No Yes Drain unit. Turn unit on with door open. Add two gallons of water THROUGH TROUGH. Close door. Wait 10 minutes. Open door. Depress and hold door switch. Does unit have water? Add water according to start- up instructions on door. Wait 5 minutes, light should go off. Is b

heruntergeladen wurde: 1   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Check voltage across terminals 1 and 2 of terminal block (see Figure 7 on page 24). Yes No Replace control panel fuses. No Yes Does voltage match serial plate voltage? No Yes Does voltage match serial plate voltage? Does voltage match serial plate voltage? DISCONNECT POWER AT CIRCUIT BREAKER. Check resistance between contactor terminals (see Figure 8 on page 25). Test power switch or adjust so Replace “ON” light; that it is actuated properly by continue on next page. cam on valve shaft. Replace

heruntergeladen wurde: 7   Dateigröße: 1 mb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Figure 6 90° Air Gap Air Gap Air Gap Stand Pipe Floor Drains INSTALLATION OPERATOR’S MANUAL 1183437 PAGE 11 OPERATION SEZ SERIES COUNTERTOP STEAMERS OPERATION OPERATION STARTUP 1. Turn lever to “ON” position. 2. Unit will fill automatically and be ready for operation in 11 minutes. NOTICE: WATER SPECIFICATION To meet warranty requirements, supply water must meet the following specification: Total Dissolved Solids (TDS) ...........60 PPM Hardness..........................................2 Grains

heruntergeladen wurde: 3   Dateigröße: 974 kb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

DISCONNECT POWER AT CIRCUIT BREAKER. 2. Remove rear cover from unit. 3. Disconnect float switch lead wires from wires B40 and B42. 4. Disconnect wires B73 and B74 from the pressure switch. 5. Remove lid from float box. 6. Make sure float travels freely along stem of float switch. 7. Place test leads in float switch terminals as shown. 8. Hold lid in same orientation as when installed. 9. Check continuity. There should be continuity. Replace as necessary. 10. Flip lid over. 11. Check for continui

heruntergeladen wurde: 1   Dateigröße: 974 kb   Hersteller: Southbend  
Kategorie: Dampfgarer
@name

Failure to do so could result in serious injury or damage. Drains must be kept clean and clear of debris. ! WARNING: SHOCK HAZARD DO NOT GET WATER IN THE CONTROLS. This could result in expensive repairs and/or electrical shock. De-energize all power to equipment before cleaning the equipment. DAILY CLEANING 1. Turn lever to the “OFF” position. 2. Remove pan guides. 3. Clean all interior surfaces with soap, water, and a non-metallic pad. Occasional use of a deliming solution such as Lime-A-Way is